Inspection
Inspection Details
Equipment ID
24587
24587
Inspection Date
11/20/2023
11/20/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
Michael Bailey
Michael Bailey
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
26
26
External ID
17f07106-1954-46bb-96b1-cf9eb6de14a8
17f07106-1954-46bb-96b1-cf9eb6de14a8
Location
Ballpark Village Office
6 Cardinal Way, St. Louis, MO
Phone: (314) 372-4568
6 Cardinal Way, St. Louis, MO
Phone: (314) 372-4568
Owner
Attn: Ballpark Village
Ballpark Village
6 Cardinal Way, St. Louis, MO 63102
Phone: (000) 000-0000
Email: Billing@stlballparkvillage.com
Ballpark Village
6 Cardinal Way, St. Louis, MO 63102
Phone: (000) 000-0000
Email: Billing@stlballparkvillage.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.8 - Hoistway enclosure | 8.11.2.1.4(h) | Yes | No | Fill all holes and voids in hoistway. | 12/5/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Yes | No | Provide fire extinguisher in machine space. | 12/5/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall work. | 12/5/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.2-2.27.8 | Yes | Yes | Smokes and heats shall work. | 12/5/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Repair stuck front and rear in car door operation buttons | 11/12/2025 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | All elevators are required to be tested under emergency power. | 11/20/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Repair stuck front & rear door operation buttons | 11/12/2025 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | All elevators are required to be tested under emergency generator annually. Re-inspection required | 1/28/2025 |
| A17.1-2016 : Elevators | 2.29 - Car and counterweight safeties | 8.6.4.20.1 | Yes | No | Need to test car safeties at rated speed with rated load. Re-inspection required | 2/7/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Need to repair stuck and damaged door open and door close buttons | 11/12/2025 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | Need to test elevator for operation on emergency power. Re-inspection required | 2/7/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Need to repair stuck and damaged door open and door close buttons | 11/12/2025 |
| A17.1-2016 : Elevators | 2.29 - Car and counterweight safeties | 8.6.4.20.1 | Yes | No | Need to test car safeties at rated speed with rated load. Re-inspection required | 11/12/2025 |
| A17.1-2016 : Elevators | 2.29 - Car and counterweight safeties | 8.6.4.20.1 | Yes | No | Need to test car safeties at rated speed with rated load. Re-inspection required |