Inspection
Inspection Details
Equipment ID
23537
23537
Inspection Date
12/5/2023
12/5/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
380
380
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
16
16
External ID
b0bb30d4-7930-455a-b0c6-8572d7256b89
b0bb30d4-7930-455a-b0c6-8572d7256b89
Location
The Beatrice
1910 Washington Ave, St. Louis, MO
Phone: (314) 474-8030
1910 Washington Ave, St. Louis, MO
Phone: (314) 474-8030
Owner
Attn: 1900 Washington Partners LLC
1900 Washington Partners LLC
393 N Euclid Ave, Ste 300, St. Louis, MO 63108
Phone: (314) 361-7117
1900 Washington Partners LLC
393 N Euclid Ave, Ste 300, St. Louis, MO 63108
Phone: (314) 361-7117
Billing
Attn: Maintenance
1900 Washington Partners, LLC c/o AHRA
6255 Knox Industrial Dr, St. Louis, MO 63139
Phone: (314) 773-1700
Email: lisa@ahrealtyadvisors.com
1900 Washington Partners, LLC c/o AHRA
6255 Knox Industrial Dr, St. Louis, MO 63139
Phone: (314) 773-1700
Email: lisa@ahrealtyadvisors.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | Provide a current tested fire extinguisher in the elevator machine room. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | No | No | Provide feeder location on main line and 110v disconnect. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display a copy of the current state operating certificate. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.15 - sign and operating device symbols | 8.11.2.1.1(o) | No | No | Post elevator lobby warning placards on all floors. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.9 - Floor and emergency identification numbering | 8.11.2.1.3(o) | No | No | Provide elevator numbering inside hoistway at all doors. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide a completed maintenance control program (MCP) on site. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide a code compliant MCP including onsite documents. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.9 - Floor and emergency identification numbering | 8.11.2.1.3(o) | No | No | Provide floor numbering on inside of hoistway doors. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.9 Elevator Corridor Call Station Pictograph | No | No | Provide "In case of fire" signage on all floors. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.4 - Normal terminal stopping devices | 8.11.2.2.5 | Yes | No | The bottom limit switch shall be adjusted to stop the movement of the car prior to striking the buffer. | 3/2/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.5 - Normal terminal stopping device | 8.11.2.1.3(g) | Yes | No | The upper terminal device shall be adjusted to stop the movement of the car prior to contacting the directional limit switch. | 3/2/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.9 - Floor and emergency identification numbering | 8.11.2.1.3(o) | No | No | Hoistways shall have floor numbers, not less than 4 inches in height, on the hoistway side of the hoistway door. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 8.11.2.1.3(w) | No | No | Stops shall be provided to prevent hoistway door hangers from overrunning the track. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.9 - Power closing of doors or gates | 8.11.2.1.1(i) | No | No | The door data plate shall be completed with the door speeds. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.4 - Sills and car floor | 8.11.2.1.1(d) | No | No | There is missing carpet inside the car that creates an unlevel and unsafe surface. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.12 - Car enclosure | 8.11.2.1.1(l) | No | No | The position indicator shall be securely attached to the car enclosure. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The emergency two-way communication does not work when car 110v removed. | 3/2/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The emergency recording gives the wrong location. | 3/2/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.4 - Normal terminal stopping devices | 8.11.2.2.5 | Yes | No | The bottom limit switch shall be adjusted to stop the movement of the car prior to striking the buffer. | 4/25/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.5 - Normal terminal stopping device | 8.11.2.1.3(g) | Yes | No | The upper terminal device shall be adjusted to stop the movement of the car prior to contacting the directional limit switch. | 4/25/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the machine room, in a noncombustible frame with a clear protective vision plate over it. | 10/22/2025 |