Inspection
Inspection Details
Equipment ID
16501
16501
Inspection Date
1/8/2024
1/8/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Brenton Lane
Brenton Lane
Relief Valve Pressure
Na
Na
Slide
6”
6”
Governor Rope Pull
35/420
35/420
Door Closing Force
Na
Na
External ID
590b695c-f1d6-4f0c-a8a2-7e78c6c4e98c
590b695c-f1d6-4f0c-a8a2-7e78c6c4e98c
Location
Hampden Hall Apts
4400 McPherson Ave, St. Louis, MO
Phone: (314) 652-4400
4400 McPherson Ave, St. Louis, MO
Phone: (314) 652-4400
Owner
Attn: Revival STL Construction, LLC
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | No | No | Each freight car shall have a solid enclosure of at least 6' in height. The space between the solid section and the top of car top shall be covered solid or with perforated or lattice-type work. The perforated or lattice work shall reject a ball 1.5" in diameter. Replace the missing panel. | 4/19/2019 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | All electrical wiring in the hoistway shall be enclosed in metal conduit, flexible conduit, or metal raceway to be in compliance with NFPA 70, National Electric Code. The first landing hoistway door interlock is missing its cover and shall be replaced. | 4/19/2019 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)2 | Yes | No | All electric elevators shall have upper and lower final limit switches. Elevator will not hit top final limit due to suspension rope stretching. The suspension ropes shall be shortened to allow testing of top final limit. | 8/13/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Phase 2 fire service does not work, and shall be repaired and tested. | 8/13/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | The phase 1 & phase 2 fire service key switches shall be legible. | 9/30/2019 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | Yes | No | Phase 2 fire service shall be operational. | 2/26/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | The car top light shall be operational and shall be guarded. | 9/30/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | The machine room fire extinguisher is expired and shall be serviced or replaced. | 9/30/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | The machine room shall be kept clean. | 9/30/2019 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The debris in the pit shall be removed. The pit shall be kept clean. | 9/30/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency phone does not work. | 4/27/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Secure unlocked hoistway lock boxes, top and bottom. | 3/1/2022 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Replace missing duct covers, wiring exposed at lower level. | 3/1/2022 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Replace missing covers on duct at top of hoistway and on 1st floor interlock | 12/30/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)4 | No | No | Replace missing gate handles and hand guards on car gate | 12/30/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current state operating certificate shall be displayed in machine room | 12/30/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Repair inoperative emergency light | 1/19/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | Repalace broken door clutch assembly on basement door | 1/19/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | Yes | No | Remove non elevator related wiring from elevator pit | 1/19/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Cat 5 incomplete.. Provide governor PO/PT, record results. | 1/8/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Cat 5 incomplete. Provide electrical switch and mechanical jaw of governor to be tested. Record results. | 1/8/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Cat 5 incomplete. Provide 125% brake test. | 1/8/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Cat 5 incomplete. Provide full load safety test., record slide. | 1/8/2024 |
| A17.1-2016 : Elevators | 4.2 - Hoistway doors | 8.6.4.13 Door Systems | Yes | No | All landing and car -door or gate mechanical and electrical components shall be maintained to ensure safe and proper operation including but not limited to, the following: (a) hoistway door interlocks or mechanical locks and electric contacts, (b) car door electric contacts, (e) Hoistway door unlocking devices, (f) hangers, tracks, door rollers, and up-thrusts, (h) sills and bottom guides, fastenings, condition, and engagement. (k) door closers, where required. | 7/29/2026 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.3 Maintenance Personnel | No | No | Maintenance, repairs, replacement , and test shall be performed only by elevator personnel. | 7/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | Repair landing control stopping failures, car goes past landing it's called to stopping about halfway between that landing and the next landing. When called to the top landing it went past hitting hitting final and became stuck in the overhead. | 7/29/2026 |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.10.2.2.2(hh) | Yes | No | A marking plate with the new car speed, governor trip speed, and pull out shall be attached to the governor. | |
| A17.1-2016 : Elevators | 2.6 - Ventilation | 2.7.9.2 | Yes | No | Machine room shall be provided with means to keep the air temp and humidity in the range of the controller OEM to ensure same and normal operation (32degrees to 104 degrees with 95% non-condensing humidity) | |
| A17.1-2016 : Elevators | 3.27 - Crosshead Data Plate and Rope Data Tags | 8.10.2.2.3(k) | Yes | No | Crosshead data plate shall be marked with new car speed, rated load, and rope data. |