Inspection
Inspection Details
Equipment ID
18916
18916
Inspection Date
1/8/2024
1/8/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Gallaher
Michael Gallaher
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
4b9ff0b5-3f52-485a-8413-65dd700e221f
4b9ff0b5-3f52-485a-8413-65dd700e221f
Location
Horseshoe Casino
999 N 2nd St, St. Louis, MO
Phone: (314) 881-7782
999 N 2nd St, St. Louis, MO
Phone: (314) 881-7782
Owner
Attn: Four Seasons Hotel
Four Seasons Hotel
999 N 2nd St, St. Louis, MO 63102
Phone: (314) 881-2072
Four Seasons Hotel
999 N 2nd St, St. Louis, MO 63102
Phone: (314) 881-2072
Billing
Attn: Andy Nowell
Four Seasons Hotel
999 N 2nd St, St. Louis, MO 63102
Phone: (314) 881-2072
Email: anowell@caesars.com
Four Seasons Hotel
999 N 2nd St, St. Louis, MO 63102
Phone: (314) 881-2072
Email: anowell@caesars.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Moving Walks | 9.3 - Handrails | 902.4 | No | No | Both handrails have cracks. Replace | |
| A17.1-1996 : Moving Walks | 9.5 - Lighting | 906.2 | No | No | Demarcation lights on both ends are out. | |
| A17.1-1996 : Moving Walks | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | No | No | Display updated certificate in machine room. | |
| A17.1-1996 : Moving Walks | 9.7 - Combplates | 902.8 | No | No | Replace two upper comb sections within 30 days. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Moving Walks | 7.3 - Handrails | 8.6.9.1 | No | No | Right handrail is cracked. Replace. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Moving Walks | 9.3 - Handrails | 8.11.4.2.13 | No | No | Left handrail has multiple cracks, must be replaced | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Moving Walks | 9.5 - Lighting | 8.6.11.5(i) Demarcation Lighting Moving Walk (Re-Inspection) | Yes | No | Demarcation lights on controller side need to be replaced. Re-inspection required | 1/8/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Moving Walks | CSR 40-5.100 State Operating Certificate | 5.100 Display of Certificate | No | No | A copy of the current state operating certificate shall be on display in the machine room | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Brake torque shall be tested, inspection team was unable to check the brake torque. Re-inspection required | 1/8/2024 |
| Missouri Minimum : Moving Walks | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.9.1 Moving Walk Handrails | No | No | Left handrail has cracks, needs to be replaced | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Bolt on brake is stripped, unable to check brake torque, need to replace bolt | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Moving Walks | 9.5 - Lighting | 8.6.11.5(i) Demarcation Lighting Moving Walk (Re-Inspection) | Yes | No | Demarcation lights on controller side need replaced | |
| Missouri Minimum : Moving Walks | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Brake torque needs to be tested. Re-inspection required |