Inspection
Inspection Details
Equipment ID
3657
3657
Inspection Date
10/23/2018
10/23/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Alfred Davis
Alfred Davis
Mechanic Name
Jamon Gray
Jamon Gray
Relief Valve Pressure
Slide
Governor Rope Pull
0
0
Door Closing Force
30
30
External ID
6c4935a1-3cd9-4cf5-871e-e0f3b28bc266
6c4935a1-3cd9-4cf5-871e-e0f3b28bc266
Location
Sky 11
331 PARK CENTRAL E, SPRINGFIELD, MO
331 PARK CENTRAL E, SPRINGFIELD, MO
Owner
Downtown Springfield Properties
333 PARK CENTRAL E STE 214, SPRINGFIELD, MO 65806-2208
333 PARK CENTRAL E STE 214, SPRINGFIELD, MO 65806-2208
Billing
Attn: Vecino Group
305 W COMMERCIAL ST, SPRINGFIELD, MO 65803-2667
305 W COMMERCIAL ST, SPRINGFIELD, MO 65803-2667
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Need current operating certificate posted in machine room. | 5/15/2024 |
| conversion | conversion | n/a | No | No | Gate switch breaks over 2"- Reduce/adjust | 5/15/2024 |
| conversion | conversion | n/a | No | No | Replace GFCI in pit | 5/15/2024 |
| conversion | conversion | n/a | No | No | Door torque over 30 pounds. Adjust | 5/15/2024 |
| conversion | conversion | n/a | No | No | Need current fire extinguisher in machine room | 5/15/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Need current operating certificate | 10/16/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Clean Machine Room | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Phone failed | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No Maintenance Records | 5/15/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Install Gard rail on ladder that allows egress to machine room (height of approximately 25' with an angle of 70% ) | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | Fireman's recall is to be checked monthly | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Phase I key switch requires replacing | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No Records | 4/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Ladder for Egress/Access to equipment room needs a back cover ladder approximately 25' @ an angle of about 75 degree. | 4/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Ropes under sized | 5/20/2024 |