Inspection
Inspection Details
Equipment ID
3658
3658
Inspection Date
10/23/2018
10/23/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Alfred Davis
Alfred Davis
Mechanic Name
Jamon Gray
Jamon Gray
Relief Valve Pressure
Slide
Governor Rope Pull
0
0
Door Closing Force
27
27
External ID
edb428cb-6357-4fd3-ac2f-54e91172ba7a
edb428cb-6357-4fd3-ac2f-54e91172ba7a
Location
Sky 11
331 PARK CENTRAL E, SPRINGFIELD, MO
331 PARK CENTRAL E, SPRINGFIELD, MO
Owner
Downtown Springfield Properties
333 PARK CENTRAL E STE 214, SPRINGFIELD, MO 65806-2208
333 PARK CENTRAL E STE 214, SPRINGFIELD, MO 65806-2208
Billing
Attn: Vecino Group
305 W COMMERCIAL ST, SPRINGFIELD, MO 65803-2667
305 W COMMERCIAL ST, SPRINGFIELD, MO 65803-2667
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Gate switch breaks over 2"- Reduce/Adjust | 3/25/2020 |
| conversion | conversion | n/a | No | No | Need current operating certificate posted in machine room | 3/25/2020 |
| conversion | conversion | n/a | No | No | Replace GFCi in pit | 3/25/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Need current operating certificate | 3/25/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine Room needs cleaning | 4/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Install Gard rail on ladder that allows egress to equipment room. (Ladder approximately 25" at an angle of 70* with no back Gard) | 4/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Hoist ropes roughing/required to be replaced | 2/11/2022 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | Yes | Yes | Unit has been RED TAGGED Could not preform 125% brake test would not pick load | 2/11/2022 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Hoist ropes showing roughing under sized | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No records | 4/3/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | To be checked monthly | 4/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Access ladder to equipment room has no back guard railing 25' rise with an angle of approximately 70 degrees | 4/3/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Phase I key switch needs replacing | 4/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Under sized required to be replaced | 5/20/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No records | 4/3/2026 |