Inspection
Inspection Details
Equipment ID
21522
21522
Inspection Date
5/17/2017
5/17/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Unknown Conversion
Unknown Conversion
Mechanic Name
Relief Valve Pressure
n/A
n/A
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
Location
Parkwood Senior Apartments
1200 North Rangeline Rd, Joplin, MO
Phone: (417) 622-0022
1200 North Rangeline Rd, Joplin, MO
Phone: (417) 622-0022
Owner
Parkwood Senior Apartments
1200 North Rangeline Rd, Joplin, MO 64801
1200 North Rangeline Rd, Joplin, MO 64801
Billing
Attn: Parkwood Senior Apartments
1200 North Rangeline Rd, , MO 64801
1200 North Rangeline Rd, , MO 64801
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | control wiring diagrams need to be on job site | 9/12/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | No | No | 620-85 Nec reccepticle needs to be a GFCI in machine room | 9/12/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.6 - Ventilation | 8.11.2.1.2(f) | No | No | air conditioner needs repaired in machine room | 9/12/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | emergency light is on all the time | 8/27/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | telephone will not call out | 8/27/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | G(1). EBR (Emergency Brake Release) unplugged. Shall be repaired/replaced, (REINSPECTION REQUIRED) | 10/14/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Emergency communications loss monitor shall work. | 3/8/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self-closing and self-locking. Does not close completely to latch. | 3/8/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil log &Fire service log, recorded monthly. (Provided by Elevator Serv Co.) | 3/8/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 | No | No | 2.7.5.1 : Machinery Space lighting (top of hoistway) not working. | 3/8/2023 |