Inspection
Inspection Details
Equipment ID
5745
5745
Inspection Date
1/31/2024
1/31/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
F. Scott Gibson
F. Scott Gibson
Mechanic Name
Charles Feagans
Charles Feagans
Relief Valve Pressure
n/a
n/a
Slide
12 inches
12 inches
Governor Rope Pull
PT400fp
PT400fp
Door Closing Force
18
18
External ID
6304a981-4fc3-43ef-9411-922bee235f5b
6304a981-4fc3-43ef-9411-922bee235f5b
Location
Dairi-Concepts
365 W US Hwy 54, El Dorado Springs, MO
Phone: (417) 808-0193
365 W US Hwy 54, El Dorado Springs, MO
Phone: (417) 808-0193
Owner
Attn: Bill Pruyne
Dairi-Concepts
365 W US Hwy 54, El Dorado Springs, MO 64744
Phone: (417) 430-2533
Email: bpruyne@dfamilk.com
Dairi-Concepts
365 W US Hwy 54, El Dorado Springs, MO 64744
Phone: (417) 430-2533
Email: bpruyne@dfamilk.com
Billing
Attn: Sammy Paris
Dairi-Concepts
365 W US Hwy 54, El Dorado Springs, MO 64744
Phone: (000) 000-0000
Alt Phone: (417) 296-2125
Email: Sparis@dfamilk.com
Dairi-Concepts
365 W US Hwy 54, El Dorado Springs, MO 64744
Phone: (000) 000-0000
Alt Phone: (417) 296-2125
Email: Sparis@dfamilk.com
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.2-2.27.8 | x | x | Phase I will not put elevator on phase I operation--this unit is exempt from smoke detectors due to enviroment | 8/27/2019 |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.2 - Car top light and outlet | 8.11.2.1.3(b) | Inspection station light needs guarded | 3/30/2022 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)6 | reopening device is not working | 3/30/2022 | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | needs current certificate posted in machine room | 3/30/2022 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | hall door gibs missing on floors 2,3 & 5 | 3/30/2022 | ||
MO Minimum : Elevators | (A) - Hoistways | (A)16 | electrical raceway on car top wires grounding needs repaired and raceway resecured | 3/30/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.1 - Operation of elevators under fire and other emergency conditions (A17.1b-1973 through A17.1b-1980) | 8.6.10.1 | x | x | Because of atmospheric conditions smoke are not used however Phase I & II still need to operate as designed, if not corrected withen 30 days the elevator will be RED TAGGED | 11/3/2020 |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | Door pressure exceeds 30lbs | 3/30/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.1 - Operation of elevators under fire and other emergency conditions (A17.1b-1973 through A17.1b-1980) | 8.6.10.1 | x | x | Ref A17.1- 6.1.2(a)(4) Phase I Recall failed. This Violation was noted on 8/27/19 annual inspection & had not been corrected. Must Re-inspect when Violation is Corrected. Placed a Red Tag and locked out the Equipment. | 9/30/2021 |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.2 - Car top light and outlet | 8.11.2.1.3(b) | Inspection station light needs guarded | 9/30/2021 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)6 | reopening device is not working | 9/30/2021 | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | needs current certificate posted in machine room | 9/30/2021 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | hall door gibs missing on floors 2,3 & 5 | 9/30/2021 | ||
MO Minimum : Elevators | (A) - Hoistways | (A)16 | electrical raceway on car top wires grounding needs repaired and raceway resecured | 9/30/2021 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | Door pressure exceeds 30lbs | 9/30/2021 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.2 - Car top light and outlet | 8.11.2.1.3(b) | Inspection station light needs guarded | 12/2/2021 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)6 | reopening device is not working | 12/2/2021 | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | needs current certificate posted in machine room | 12/2/2021 | ||
MO Minimum : Elevators | (A) - Hoistways | (A)16 | electrical raceway on car top wires grounding needs repaired and raceway resecured | 12/2/2021 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | Door pressure exceeds 30lbs | 12/2/2021 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | hall door gibs missing on floors 2,3 & 5 | 12/2/2021 | ||
A17.1-2016 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | x | ASME A17.1 Section 2.7.3.4.1(a)(b) Door Closure shall be added and the locking mechanism requires changed. | 1/31/2024 | |
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.2 Phase I Operation Recall by Initiating Device | x | x | ASME A17.1 Section 2.27.3.2.3 could not be verified due to the Fire Alarm Personnel were not available on the day of the test. Did not Red Tag elevator has not been turned over for service. The reinspection is still in process due to Electronic Drive issues, | 1/31/2024 |