Inspection
Inspection Details
Equipment ID
21303
21303
Inspection Date
2/15/2024
2/15/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Tim Crafton
Tim Crafton
Mechanic Name
Brant Willtrout
Brant Willtrout
Relief Valve Pressure
540
540
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
9b8fab63-491b-4d3f-8719-6056289c7ceb
9b8fab63-491b-4d3f-8719-6056289c7ceb
Location
Mineral Area Community College
5270 Flat River Dr, Park Hills, MO
Phone: (573) 431-4593
5270 Flat River Dr, Park Hills, MO
Phone: (573) 431-4593
Owner
Attn: Rodney Resinger
Mineral Area Community College
5270 Flat River Dr, Park Hills, MO 63601
Phone: (573) 760-7899
Email: lballew@mineralarea.edu
Mineral Area Community College
5270 Flat River Dr, Park Hills, MO 63601
Phone: (573) 760-7899
Email: lballew@mineralarea.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | A17.1 ITEM 1.5(b) AUXILLARY ILLUMINATION: EMG LIGHTS NOT WORKING, BOARD PROBLEM | 5/15/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | A17.1 ITEM ITEM 1.6 CAR EMERGENCY SIGNAL: ALARM BELL NOT WORKING ON AUXILLARY POWER: BOARD PROBLEM | 5/15/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | OSV NOT SEALED TEST DUE IN 2021 (A17.1 8.6.5.16.5) | 12/2/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(c)(1) | No | No | 8.6.1.4.1(c)(1) A record of oil usage (8.6.5.7). PROVIDE OIL USAGE LOG. | 12/2/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(c)(2) | No | No | 8.6.1.4.1(c)(2) A record of findings for firefighters’ service operation required by 8.6.11.1 with identification of the person(s) that performed the operation. PROVIDE FIRE SERVICE TEST LOG. | 12/2/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(c)(3) | No | No | 8.6.1.4.1(c)(3) Periodic tests (see 8.6.1.7) shall be documented or recorded in accordance with 8.6.1.7.2. PROVIDE TEST LOG. | 12/2/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.2 Callbacks (Trouble Calls) Documentation | No | No | 8.6.1.4.2 Callbacks (Trouble Calls). A record of callbacks shall be maintained and shall include the description of reported trouble, dates, time, and corrective action(s) taken that are reported by any means to elevator personnel. PROVIDE CALLBACK LOG. | 12/2/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | No | No | 8.6.1.6 General Maintenance Methods and Procedures PROVIDE COPY OF TEST METHODS & PROCEDURES. | 12/2/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | OSV testing is past due, needs to be performed within 30 days. Re-inspection required | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency lights shall be made operational. Re-inspection required | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm shall be made operational. Re-inspection required |