Inspection
Inspection Details
Equipment ID
15218
15218
Inspection Date
2/13/2024
2/13/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Tom Worsham
Tom Worsham
Relief Valve Pressure
NA
NA
Slide
Not complete
Not complete
Governor Rope Pull
300/850
300/850
Door Closing Force
25
25
External ID
3bce81a5-7db3-4e28-9f4b-bdbbee17e70a
3bce81a5-7db3-4e28-9f4b-bdbbee17e70a
Location
Frisco Building
906 Olive St, St. Louis, MO
Phone: (314) 432-2222
906 Olive St, St. Louis, MO
Phone: (314) 432-2222
Owner
Attn: Maria Pressley
Cas-Mizzou-Neda, LLC
906 Olive St, PH #3, St. Louis, MO 63101
Phone: (314) 621-7300
Email: mariafrisco906@gmail.com
Cas-Mizzou-Neda, LLC
906 Olive St, PH #3, St. Louis, MO 63101
Phone: (314) 621-7300
Email: mariafrisco906@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | Yes | No | Cab stop switch alarm inoperative. Repair | 1/23/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Replace sheave liners. | 1/16/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Hands free cab phone inoperative. Repair - possible lost signal. | 12/9/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Replace drywall in hoistway that has been cut out on 3rd floor. | 1/16/2025 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Phase II does not work in car. Repair within ten (10) days or red tag unit. | 7/1/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Cat 5 full load testing is overdue. Perform required testing. Re-inspection required | 12/22/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 1/16/2025 |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 2.18.9 | Yes | No | Overspeed governor was replaced at an earlier time and was recalibrated, but the data plate was not changed to reflect changed. Replace plate with one that has correct information. Re-inspection required, but can be performed at a time of completion of 5 yr testing | 2/13/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | 5 year inspection was started, but not completed. Need to preform full load full speed car safeties, 125% brake test, full load full speed car buffer, counterweight buffer, governor rope pull out, governor rope pull thru. Re-inspection required within 90 days | 2/13/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Cat 5 testing incomplete - governor trip speeds need tested and car set on safeties to complete cat 5 testing | 2/28/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 1/16/2025 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Both alarm bell buttons are not working correctly, need to be replaced. Re-inspection required | 12/4/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 1/16/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 1/16/2025 |