Inspection
Inspection Details
Equipment ID
16825
16825
Inspection Date
11/6/2018
11/6/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Tim Crafton
Tim Crafton
Mechanic Name
Relief Valve Pressure
445
445
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
acf6f918-c763-4a39-a188-e31bc20a2086
acf6f918-c763-4a39-a188-e31bc20a2086
Location
Kasey Paige assisted Living Center
3715 JAMIESON AVE, SAINT LOUIS, MO
3715 JAMIESON AVE, SAINT LOUIS, MO
Owner
Kasey Paige assisted Living LLC
1869 CRAIG PARK CT, SAINT LOUIS, MO 63146-4122
1869 CRAIG PARK CT, SAINT LOUIS, MO 63146-4122
Billing
Attn: Kasey Paige assisted Living Center
1869 CRAIG PARK CT, SAINT LOUIS, MO 63146-4122
1869 CRAIG PARK CT, SAINT LOUIS, MO 63146-4122
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | NO CERTIFICATE DISPLAYED | 12/13/2018 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | CLEAN PIT | 12/13/2018 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11.3.2.2 Cylinders Test shall be performed | Yes | No | Elevator stopped during testing. Will need to trouble-shoot and resume testing upon repair. | 12/10/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | No storage in machine room. | 12/27/2019 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned. | 12/27/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Car door restrictor does not work. Repair or replace. | 11/3/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned. | 12/31/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current state operation certificate shall be displayed in machine room | 12/31/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Car door restrictor is missing parts. Replace & adjust same | 12/3/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher in machine room is expired. Replace or have serviced | 12/31/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Restrictor failed | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher not current | 12/31/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the state operating certificate shall be posted in elevator equipment room | 12/31/2024 |
| A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | Yes | No | Door restrictor inoperable. Re-inspection required | 12/31/2024 |