Inspection
Inspection Details
Equipment ID
14852
14852
Inspection Date
11/6/2018
11/6/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Jeffrey Miller
Jeffrey Miller
Relief Valve Pressure
390
390
Slide
Governor Rope Pull
Door Closing Force
27/26
27/26
External ID
468271c4-cfb0-4bfa-8c10-6c8874de2ba1
468271c4-cfb0-4bfa-8c10-6c8874de2ba1
Location
Hampton Inn & Suites
5650 OAKLAND AVE, SAINT LOUIS, MO
5650 OAKLAND AVE, SAINT LOUIS, MO
Owner
Hampton Inn & Suites- Forest Park
5650 OAKLAND AVE, SAINT LOUIS, MO 63110-1316
5650 OAKLAND AVE, SAINT LOUIS, MO 63110-1316
Billing
Attn: Hampton Inn & Suites- Forest Park
5650 OAKLAND AVE, SAINT LOUIS, MO 63110-1316
5650 OAKLAND AVE, SAINT LOUIS, MO 63110-1316
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Repair emergency light in car | 12/13/2018 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | provide monthly fire service test & document on log in machine room | 2/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | provide maintenance control program | 2/1/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 2/1/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test & document on log in machine room | 2/1/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Celan oil from the pit floor | 2/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide maintenance control program | 2/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | Yes | No | Repair/replace leaking overspeed valve & perform 5 year test;; Reinspection required | 12/5/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean oil from pit floor | 12/31/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required shall be provided in the machine room. | 12/8/2025 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | Yes | No | On fire service, doors will not close. Take corrective action and re-test. | 8/18/2025 |
| A17.1-1996 : Elevators | 1.16 - Rated load, platform area, and data plate | 207 | No | No | Capacity tag shall be installed in car. | 12/8/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Elevator dropped during 1st static test. Unit stayed level during 2nd static test but the valbe to the take was shut off. Repair valve as required. | 4/30/2026 |