Inspection
Inspection Details
Equipment ID
17377
17377
Inspection Date
10/22/2018
10/22/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Jeffrey Dooley
Jeffrey Dooley
Relief Valve Pressure
370
370
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
e3791636-bf32-40fe-aa34-fc2a912c5ad4
e3791636-bf32-40fe-aa34-fc2a912c5ad4
Location
Metro Lofts
4555 FOREST PARK AVE, SAINT LOUIS, MO
4555 FOREST PARK AVE, SAINT LOUIS, MO
Owner
Metro Lofts LLC
4535 FOREST PARK AVE, SAINT LOUIS, MO 63108-2128
4535 FOREST PARK AVE, SAINT LOUIS, MO 63108-2128
Billing
Attn: Metro Lofts
4535 FOREST PARK AVE STE 109, SAINT LOUIS, MO 63108-2129
4535 FOREST PARK AVE STE 109, SAINT LOUIS, MO 63108-2129
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate. | 12/3/2018 | ||
A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | x | OSV is not sealed and must have a cat 5 weight test performed within 90 days or less | 1/11/2024 | |
A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | auxiliary power lowering unit does not work. | 1/11/2024 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | clean dirt from elevator car top. | |||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | elevator cab phone does not work. repair phone. | 1/11/2024 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current operating certificate shall be displayed in the machine room | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | A drop ceiling has been installed in this unit and the bolts going through the car top shall be cut off to prevent any tripping hazards for maintenance personnel working on the cartop. | |||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency communication inoperable. Re-inspection required | 2/26/2025 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State Elevator Certificate. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | x | Clean the car top. | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | x | Clean the pit. | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Provide existing phone to work. |