Inspection
Inspection Details
Equipment ID
7243
7243
Inspection Date
2/23/2024
2/23/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Daniel Swett
Daniel Swett
Mechanic Name
Ronald Orr, Jr
Ronald Orr, Jr
Relief Valve Pressure
N/A
N/A
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
2d7a0088-b1ca-404c-9c2c-f63facf349b3
2d7a0088-b1ca-404c-9c2c-f63facf349b3
Location
Eric P Newman Educational Center
320 S Euclid Ave, St. Louis, MO
Phone: (314) 747-0740
320 S Euclid Ave, St. Louis, MO
Phone: (314) 747-0740
Owner
Attn: Matt Dissett
WUSM
660 S Euclid Ave, CB 8080, St. Louis, MO 63110
Phone: (314) 273-3124
Fax: (314) 747-0727
Email: mdissett@wustl.edu
WUSM
660 S Euclid Ave, CB 8080, St. Louis, MO 63110
Phone: (314) 273-3124
Fax: (314) 747-0727
Email: mdissett@wustl.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Demarcation lights are not working. | 4/14/2020 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Demarcation lighting out - top and bottom. | 4/14/2020 |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.6.8.4 | No | No | Combplate impact device (vertical switch) not working at top landing. | |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.11.4.1(g) | No | No | Combplate tooth broken at top landing. | |
| A17.1-2016 : Elevators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3.3 | No | No | Step/skirt performance index over maximum allowable. | |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.6.8.4 | No | No | Combplate impact device setting (vertical plane) at top landing of escalator over allowable limit. | |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.6.8.4 | No | No | Combplate impact device (vertical switch) not working at top landing. | |
| A17.1-2016 : Elevators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3.3 | No | No | Step/skirt performance index over maximum allowable. | |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Demarcation lighting not working (both top and bottom). | |
| A17.1-1996 : Escalators | 7.1 - General fire protection | 801 | No | No | Observed opening in deck. Exterior deck plates sliding down, creating opening. | |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.6.8.4 | No | No | Combplate impact device (vertical switch) not working at top landing. | |
| A17.1-2016 : Elevators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3.3 | No | No | Step/skirt performance index over maximum allowable. | |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Demarcation lighting not working (both top and bottom). | |
| A17.1-2016 : Elevators | 7.3 - Handrails | 8.6.8.1 | No | No | Handrails cracking, presenting pinch points. Both handrails. |