Inspection
Inspection Details
Equipment ID
7507
7507
Inspection Date
4/9/2024
4/9/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michial Linenfelser
Michial Linenfelser
Mechanic Name
Michael Vantassel
Michael Vantassel
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
Incomplete
Incomplete
External ID
221da1cd-a102-472b-a165-6483d8049c88
221da1cd-a102-472b-a165-6483d8049c88
Location
Revival STL Construction , LLC
5522 DELMAR BLVD, SAINT LOUIS, MO
Phone: (417) 425-1346
5522 DELMAR BLVD, SAINT LOUIS, MO
Phone: (417) 425-1346
Owner
Attn: Revival STL Construction, LLC
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Door closing force shall be less than 30 | 6/3/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | On Phase II door does not close when door open button is released | 5/8/2019 |
| conversion | conversion | n/a | No | No | Fill All Voids in hoisway in pit area - 1 near top of hoistway | 6/3/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Remove the Phase 1 fire service key switch at the basement level. | 7/17/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/15/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The machine room fire extinguisher shall have a current test tag. | 5/15/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | No | No | The door closing force shall be adjusted so it does not exceed 30 pounds. | 5/15/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | The holes in the pit wall, and near the top of the hoistway shall be sealed with approved solid materials. | 5/15/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The emergency lighting shall be operational. | 8/14/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The alarm bell shall be operational on auxiliary power. | 8/14/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | No | No | Door closing force shall be adjusted, not to exceed 30 pds. | 7/25/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Seal holes in pit wall and near top of hoistway. | 7/25/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post operating certificate in equipment room. | 4/6/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Repair inoperable audible and visual Phase I indicators | 4/9/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Repair Phase II key switch. Hold position not functioning | 4/9/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Stop switch not overridden in Phase 1 | 4/9/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Car not returning to Phase I when Phase II key is switched to off | 4/9/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 211.3a(8) Visual and audible signal | Yes | Yes | Repair inoperable audible and visual Phase I indicators. Initially sited 5/26/23. | 5/1/2024 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Repair Phase II key switch. Hold position not functioning. Initially sited 5/26/23. | 5/1/2024 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Stop switch not overridden in Phase 1. Initially sited 5/26/23. | 5/1/2024 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Car not returning to Phase I when Phase II key is switched to off. Initially sited 5/26/23. | 5/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher in the machine room shall be serviced, the last annual service tag indicates it was serviced in 2022. | 5/15/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The elevator machine room door shall be self-closing/self-locking and shall be operable from the interior space without the use of a key. | 5/15/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The testing has not been completed on the elevator at this time, the elevator was placed out of service. Only a machine room inspection was performed, a full inspection shall be performed before the annual is completed. Reinspection is required. | 5/1/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Provide signage to meet the code date of the Fire recall system (No Hold for this vintage | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Provide 2 separate car light sources | 5/15/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The elevator machine room door shall be self-closing/self-locking and shall be operable from the interior space without the use of a key. | 5/15/2024 |