Inspection
Inspection Details
Equipment ID
13581
13581
Inspection Date
4/22/2024
4/22/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Hugh Moran
Hugh Moran
Mechanic Name
Marcus Geno
Marcus Geno
Relief Valve Pressure
510
510
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
14
14
External ID
4fd9bca2-78ec-4e00-b046-e0ed7607cb10
4fd9bca2-78ec-4e00-b046-e0ed7607cb10
Location
St. Louis Union Station
1800 Market St, St. Louis, MO
Phone: (314) 421-3314
1800 Market St, St. Louis, MO
Phone: (314) 421-3314
Owner
Attn: USH, LLC
USH, LLC
111 Westport Plaza Dr, Ste 500, St. Louis, MO 63141
Phone: (000) 000-0000
Email: rhargrove@stlunionstationhotel.com
USH, LLC
111 Westport Plaza Dr, Ste 500, St. Louis, MO 63141
Phone: (000) 000-0000
Email: rhargrove@stlunionstationhotel.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Elevator pit light is not working | 2/14/2020 |
| conversion | conversion | conversion - reinspect | Yes | No | Elevator alarm bell not working | 11/7/2019 |
| conversion | conversion | n/a | No | No | Machine room lights not working | 2/14/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.1.1 | Yes | No | Machine room penetrations | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Hoistway penetration NE corner | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.1.1 | Yes | No | Install ceiling in machine room | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.11.2.2.6 | Yes | No | Heat and smokes for shunt recall | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | Yes | No | Increase pit illumination to 10 ft candles throughout measured at the floor. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Enclose top hoistway | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.5 Sump pump shall be provided | Yes | No | No oil minder on sump pump. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 | Yes | No | Machine room illumination shall be 19 ft candles throughout measured at the floor. | 2/24/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Provide source power labels on disconnect switches. | 5/13/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 5/13/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate in equipment room. | 5/13/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher is expired, have serviced or replaced | 7/3/2024 |