Inspection
Inspection Details
Equipment ID
17187
17187
Inspection Date
4/17/2024
4/17/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Vincent Langendoerfer
Vincent Langendoerfer
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
e0667bae-62fa-40a7-aa0e-7e666e2988ce
e0667bae-62fa-40a7-aa0e-7e666e2988ce
Location
Senate Apartments
265 Union Blvd, St. Louis, MO
Phone: (314) 367-7900
265 Union Blvd, St. Louis, MO
Phone: (314) 367-7900
Owner
Attn: Accounts Payable
275 on the Park
11766 Wilshire Blvd, Ste 325, Los Angeles, CA 90025
Phone: (281) 888-0832
275 on the Park
11766 Wilshire Blvd, Ste 325, Los Angeles, CA 90025
Phone: (281) 888-0832
Billing
Attn: Accounts Payable
275 on the Park - Annex
10330-DD Lake Rd, Houston, TX 77070
Phone: (281) 888-0832
Email: AP@unified-residential.com
275 on the Park - Annex
10330-DD Lake Rd, Houston, TX 77070
Phone: (281) 888-0832
Email: AP@unified-residential.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Cover hole in hoistway at basement level. | 10/18/2018 |
| conversion | conversion | n/a | No | No | Replace missing cab light bulb and properly guard lights. | |
| conversion | conversion | n/a | No | No | There shall be a light in the pit. | |
| conversion | conversion | conversion - reinspect | Yes | No | Car door restrictor shall work. | 10/18/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | In cab emergency telephone shall work. | 10/18/2018 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide code compliant machine room door handle and lock. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Replace the missing cab light bulb and properly guard lights. | |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Repair the hole in the hoistway at the basement level. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | An ABC type fire extinguisher shall be kept in the machine room. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display the current state operating certificate. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Repair the hole in the hoistway at the basement. | |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Door reopening devices that are sensitive to smoke shall be rendered inoperative on Firemans' Return service. | 9/22/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | All pipes conveying liquid, vapor, or gas that are above or near any elevator equipment shall be guarded or guttered. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | A tool to reset the car safeties shall be available on-site. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | The car door restrictor shall be operational. | 7/5/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The in car emergency telephone shall be operational. | 7/5/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | The electronic safety edge is not bypassed on Phase 1 fire recall. Take corrective action. | 7/5/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit lighting shall be operational. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Condensation dripping on duct work. All pipes conveying liquid, vapor, or gas that are above or come near elevator equipment shall be guarded or guttered. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Could not test windup safeties. A tool to reset the car safeties shall be available on-site. | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | 110V disconnect shall be labeled. Where there is more than one machine in a room, the disconnect for each machine shall be conspicuously numbered to correspond to the machine it controls. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The test is incomplete. Fire service, testing of light/alarm/phone with 110V source removed, inspection of pit, inspection of door restrictor, and inspection of hoistway need to be completed. | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 4/2/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Rope used as a connection from the safety to the governor rope, including rope wound on the safety-rope drum, shall be made of metal, and shall be corrosion resistant (currently iron/steel). Replace and retest for soft set and pullout length. | 4/17/2024 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.8.2 | Yes | No | 2.3.1 - Machine room lighting needs to be repaired. One or more bulbs is not working. | 4/17/2024 |
| A17.1-2016 : Elevators | 4.2 - Hoistway doors | 8.6.4.13 Door Systems | Yes | No | Replace missing secondary fire tab on top of 12th floor hoistway door. | 4/17/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Yes | No | Replace faded "Do not use elevator in case of fire" signage as needed. | 4/17/2024 |
| A17.1-2016 : Elevators | 2.6 - Ventilation | 2.7.9.2 | Yes | No | Machine room climate control is non-functional. | 10/8/2024 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work. Button lights up, but does not dial (communication loss works). | |
| A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | Yes | No | Car door restrictor shall work at all floors. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. |