Inspection
Inspection Details
Equipment ID
13987
13987
Inspection Date
10/31/2018
10/31/2018
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
David Tiemann
David Tiemann
Relief Valve Pressure
Slide
11
11
Governor Rope Pull
315/515
315/515
Door Closing Force
27
27
External ID
edd96f1b-adc4-47e6-aa92-3125928cbef3
edd96f1b-adc4-47e6-aa92-3125928cbef3
Location
Coronado Place
3701 LINDELL BLVD, SAINT LOUIS, MO
3701 LINDELL BLVD, SAINT LOUIS, MO
Owner
St Louis Properties
3701 LINDELL BLVD, SAINT LOUIS, MO 63108-3425
3701 LINDELL BLVD, SAINT LOUIS, MO 63108-3425
Billing
Attn: St Louis Properties
3701 LINDELL BLVD, SAINT LOUIS, MO 63108-3425
3701 LINDELL BLVD, SAINT LOUIS, MO 63108-3425
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Repair inoperable emergency phone. | 4/17/2019 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Replace earthquake halo on counterweight frame. | 4/15/2022 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working. | 4/15/2022 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not work on 110v emergency power or normal power. Repair or replace | 11/27/2023 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | Elevator car top shall remain clean to prevent any hazards | |||
MO Minimum : Elevators | (I) - Pits | (I)1 | Elevator pit shall be clean of all debris | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Elevator pit light shall work with a minimum of 5 foot candles. | |||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Up to date operating certificate is required in the machine room. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Machine room lighting shall work. No less than 10 foot candles at floor level. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | A code compliant MCP and all the on-site documentation required shall be provided in the machine room. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | Missing junction box covers on fire service wiring. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Basement hall button plate needs to be mounted securely. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | "In case of fire" pictograph is missing at call stations. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Basement Braille tag is missing. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Re-install the cover on the open air vent by the elevator equipment. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone shall work. | 12/20/2024 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | x | Lockable disconnect required. Circuit breaker shall be lockable. | 12/20/2024 | |
A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.6.4.20.2 | x | x | The maximum tripping speed for the governor is 452 fpm. It is not tripping until 500 fpm. Elevator Red Tagged. | 12/20/2024 |
MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | x | Lockable disconnect required. Circuit breaker shall be lockable. (Not corrected as of 12/20/24 re-inspection) | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone shall work. (Not corrected as of 12/20/24 re-inspection) |