Inspection
Inspection Details
Equipment ID
8981
8981
Inspection Date
3/13/2024
3/13/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Jeffrey Borgeson
Jeffrey Borgeson
Relief Valve Pressure
620
620
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
20
20
External ID
b8ebe8cf-42f4-4409-87f6-d77ebdca026f
b8ebe8cf-42f4-4409-87f6-d77ebdca026f
Location
Harrah's Casino- NKC
1 Riverboat Dr, North Kansas City, MO
Phone: (816) 889-4265
Alt Phone: (816) 365-6915
1 Riverboat Dr, North Kansas City, MO
Phone: (816) 889-4265
Alt Phone: (816) 365-6915
Owner
Attn: Harrah's Casino- NKC
Harrah's Casino- NKC
1 Riverboat Dr, N Kansas City, MO 64116
Phone: (816) 889-7034
Email: rmurphy@harrahs.com
Harrah's Casino- NKC
1 Riverboat Dr, N Kansas City, MO 64116
Phone: (816) 889-7034
Email: rmurphy@harrahs.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | the emergency light battery is dead and needs to be replaced | 1/10/2020 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1001.2(d)(12) - | No | No | when fire service phase 2 was keyed to the off position with the doors open at a floor other than the designated level, the elevator did not go back on phase 1 and return to the designated level | 1/9/2020 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | Perform monthly fire service test and post a log in the machine room | 7/21/2020 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 204.2c | No | No | repair car top a/c unit, it is in peices, needs to work for glass back elevator exposed to direct sunlight | 7/21/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | The building shall post the operating certificate in the elevator equipment room, and it needs to be updated with a new copy every year. | 7/14/2021 |
| A17.1-2016 : Elevators | 1.14 - Ventilation | 8.11.3.1.1(n) | No | No | top of car air condition unit is not in working order, repair a/c unit | 5/31/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | can not read the markings on the fire service phase 2 keyswitch collar, replace the collar | 5/31/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | can not read the markings on the in car stop keyswitch collar, replace the stop switch collar | 5/31/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | emergency light did not come on, the alarm bell did work | 5/31/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | the state operating certificate in the machine room is to be updated every year | 5/31/2022 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 204.2c | No | No | the air conditioner provided for this observation elevator is not working, there shall be a minimum air handling capacity to provide one air change per minute based on net inside car volume, with auxiliar power source | 10/24/2024 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | emergency lights did not come on, repair emergency lights | 3/13/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean off car top, air conditioning unit that hasn't worked for years should be replaced with something that works. (glass back elevator) | 10/24/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Water on the machine room floor after storm, repair leak | 10/24/2024 |
| A17.1-2016 : Elevators | 1.8 - Door closing force | 8.11.2.1.1(h) | Yes | No | Adjust car door force to be 30 lbs or less | 5/16/2025 |
| A17.1-2016 : Elevators | 4.2 - Hoistway doors | 8.6.4.13 Door Systems | No | No | Clean the unexposed hoistway sills | 7/18/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove unexposed oil absorbent pads from the pit floor | 7/18/2025 |
| A17.1-2016 : Elevators | 2.34 - Flexible Hydraulic Hose and Fitting Assemblies | 8.11.3.1.2(v) | No | No | Repair oil cooler system leak in the equipment room and clean oil from floor | 7/18/2025 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(a)(1) | No | No | Provide updated maintenance task log | 7/18/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Machine room fire extinguisher inspection tag is expired, it was due for annual inspection in February 2026. | |
| A17.1-1996 : Elevators | 1.15 - sign and operating device symbols | 1001.2(a)(15) | No | No | In case of fire use stairs signs missing on top and bottom landings | |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Emergency lights did not work even with new battery, repair wiring to the emergency lights | |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | Yes | No | Packing gland blew during pressure test, replace packing | |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Clean up oil in pit after replacing the packing | |
| A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 3.19.4.7.5(a) | Yes | No | Overspeed valve lock nut can not be broke loose to adjust the valve, replace the overspeed valve, and perform reinspection |