Inspection
Inspection Details
Equipment ID
3658
3658
Inspection Date
5/20/2024
5/20/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
7447b469-92d1-4fd2-a136-1787342d84b5
7447b469-92d1-4fd2-a136-1787342d84b5
Location
Sky 11
331 Park Central E, Springfield, MO
Phone: (417) 217-9878
331 Park Central E, Springfield, MO
Phone: (417) 217-9878
Owner
Attn: Cameron Beam
Park East LLC
318 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Park East LLC
318 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Billing
Attn: Park East LLC
Park East LLC
318 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Email: cpbeam@zoho.com
Park East LLC
318 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Email: cpbeam@zoho.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Gate switch breaks over 2"- Reduce/Adjust | 3/25/2020 |
| conversion | conversion | n/a | No | No | Need current operating certificate posted in machine room | 3/25/2020 |
| conversion | conversion | n/a | No | No | Replace GFCi in pit | 3/25/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Need current operating certificate | 3/25/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine Room needs cleaning | 4/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Install Gard rail on ladder that allows egress to equipment room. (Ladder approximately 25" at an angle of 70* with no back Gard) | 4/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Hoist ropes roughing/required to be replaced | 2/11/2022 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | Yes | Yes | Unit has been RED TAGGED Could not preform 125% brake test would not pick load | 2/11/2022 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Hoist ropes showing roughing under sized | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No records | 4/3/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | To be checked monthly | 4/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Access ladder to equipment room has no back guard railing 25' rise with an angle of approximately 70 degrees | 4/3/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Phase I key switch needs replacing | 4/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Under sized required to be replaced | 5/20/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No records | 4/3/2026 |