Inspection
Inspection Details
Equipment ID
3657
3657
Inspection Date
5/20/2024
5/20/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
7e038e98-c0d4-4fe5-9073-ff0cbfc453c7
7e038e98-c0d4-4fe5-9073-ff0cbfc453c7
Location
Sky 11
331 Park Central E, Springfield, MO
Phone: (417) 217-9878
331 Park Central E, Springfield, MO
Phone: (417) 217-9878
Owner
Attn: Cameron Beam
Park East LLC
318 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Park East LLC
318 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Billing
Attn: Park East LLC
Park East LLC
318 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Email: cpbeam@zoho.com
Park East LLC
318 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Email: cpbeam@zoho.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Need current operating certificate posted in machine room. | 5/15/2024 |
| conversion | conversion | n/a | No | No | Gate switch breaks over 2"- Reduce/adjust | 5/15/2024 |
| conversion | conversion | n/a | No | No | Replace GFCI in pit | 5/15/2024 |
| conversion | conversion | n/a | No | No | Door torque over 30 pounds. Adjust | 5/15/2024 |
| conversion | conversion | n/a | No | No | Need current fire extinguisher in machine room | 5/15/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Need current operating certificate | 10/16/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Clean Machine Room | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Phone failed | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No Maintenance Records | 5/15/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Install Gard rail on ladder that allows egress to machine room (height of approximately 25' with an angle of 70% ) | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | Fireman's recall is to be checked monthly | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Phase I key switch requires replacing | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No Records | 4/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Ladder for Egress/Access to equipment room needs a back cover ladder approximately 25' @ an angle of about 75 degree. | 4/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Ropes under sized | 5/20/2024 |