Inspection
Inspection Details
Equipment ID
23326
23326
Inspection Date
11/16/2018
11/16/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
William Gorden, Jr.
William Gorden, Jr.
Relief Valve Pressure
Slide
Governor Rope Pull
NA
NA
Door Closing Force
22
22
External ID
ef75a6b8-1c07-4210-a975-aecec1df30cc
ef75a6b8-1c07-4210-a975-aecec1df30cc
Location
Star Residences
6367 LALITE AVE, SAINT LOUIS, MO
6367 LALITE AVE, SAINT LOUIS, MO
Owner
Star Residences
6367 LALITE AVE, SAINT LOUIS, MO 63136-4700
6367 LALITE AVE, SAINT LOUIS, MO 63136-4700
Billing
Attn: Star Residences
6367 LALITE AVE, SAINT LOUIS, MO 63136-4700
6367 LALITE AVE, SAINT LOUIS, MO 63136-4700
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work when 110v disconnect is turned off. | 10/18/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Provide updated fire extinguisher. | 10/25/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide maintenance control program. | 10/25/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean pit. | 10/25/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.6 - Governor-rope tension devices | 8.11.2.1.5(g) | No | No | Tail sheave switch is wired into the safety circuit,repair as needed. | 10/26/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Expired | 10/26/2021 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Expired | 10/26/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.6 - Governor-rope tension devices | 2.18.7 | No | No | Tail sheave switch is wired into safety circuit | 1/20/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Provide existing phone to work, has power. | 1/9/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | The elevator does not operate correctly on emergency power. Re-inspection required |