Inspection
Inspection Details
Equipment ID
22461
22461
Inspection Date
5/29/2024
5/29/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
587849b9-89e1-430d-8a42-9d1177795cf8
587849b9-89e1-430d-8a42-9d1177795cf8
Location
1424 Washington Ave
1424 Washington Ave, St. Louis, MO
Phone: (314) 588-1170
1424 Washington Ave, St. Louis, MO
Phone: (314) 588-1170
Owner
Attn: Trevor Burbank
Biota Properties LLC
4579 Laclede Ave, Ste 434, St. Louis, MO 63103
Phone: (214) 641-1041
Email: trevorLburbank@gmail.com
Biota Properties LLC
4579 Laclede Ave, Ste 434, St. Louis, MO 63103
Phone: (214) 641-1041
Email: trevorLburbank@gmail.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A maintenance control program shall be kept on-site. | 6/9/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Wiring schematics shall be kept on-site. | 6/9/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | A currently tested ABC type fire extinguisher shall be located near the upper landing hoistway access entrance. | 6/9/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 8.11.2.1.3(cc) | A suspension rope data tag shall be installed that conforms to A17.1 2004 - 2.20.2.2 | 6/9/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 2.18.5 | A governor rope data tag shall be installed that conforms to A17.1 2004 - 2.18.5.3 | 6/9/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 6/1/2020 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.28 - Counterweight and counterweight buffer | 2.22 | A counterweight runby sign shall be installed in the pit according to A17.1 2004 - 2.4.5 | 6/9/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | A fire extinguisher shall be provided near the controller at the top floor. | 12/30/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.13 - Windows, projections, recesses, and setbacks | 8.11.2.1.3(s) | Landing sill guards shall be installed at the 1st and 3rd floors. | 12/30/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Maintenance control program (MCP) documentation shall be kept on-site. | 12/30/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Wiring schematics shall be kept on-site. | 12/30/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. | 4/1/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | The fire extinguisher is missing tag. Provide current tested and tagged ABC fire extinguisher. | 5/1/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | No one is answering the emergency phone. Take corrective action and re-test. | 5/29/2024 |