Inspection
Inspection Details
Equipment ID
6642
6642
Inspection Date
6/4/2024
6/4/2024
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Thomas Suedkamp
Thomas Suedkamp
Relief Valve Pressure
na
na
Slide
12
12
Governor Rope Pull
67 / 220
67 / 220
Door Closing Force
20
20
External ID
251c6fef-c5b0-4f89-9c3d-1ec1fe8c4ad4
251c6fef-c5b0-4f89-9c3d-1ec1fe8c4ad4
Location
Moonrise Hotel
6177 Delmar Blvd, St. Louis, MO
Phone: (314) 280-3057
Email: joe@moonrisehotel.com
6177 Delmar Blvd, St. Louis, MO
Phone: (314) 280-3057
Email: joe@moonrisehotel.com
Owner
Attn: Eman
Moonrise Hotels, LLC
6504 Delmar Blvd, St. Louis, MO 63130
Phone: (314) 727-8000
Email: jmoreno@moonrisehotel.com
Moonrise Hotels, LLC
6504 Delmar Blvd, St. Louis, MO 63130
Phone: (314) 727-8000
Email: jmoreno@moonrisehotel.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 8.6.4.5 | x | x | Safeties set before the minimum required slide of 10 inches. Red tagged elevator. | 6/6/2019 |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | There is no lighting in machine space on top of hoistway. | 9/16/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | 1) Permanently installed electric lighting shall be provided in all machinery spaces, machine rooms, control spaces, and control rooms. | 9/16/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | Permanently installed lighting shall be provided in all machine spaces, including top of hoistway. | 8/30/2021 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Maintenance control program shall be provided on site. | 8/30/2021 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Current operating certificate shall be displayed in machine room. | 8/30/2021 | ||
A17.1-2016 : Elevators | 1.17 - Standby power operation | 2.27.2 | x | Provide testing of elevator on emergency power.. | 9/28/2023 | |
A17.1-2016 : Elevators | 1.17 - Standby power operation | 2.27.2 | x | Provide testing of emergency generator selector switch. | 9/28/2023 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 2.11 | Provide hoistway door fire retainer, all floors. | 1/31/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 8.11.2.2.7 | x | Provide testing of the elevator on emergency power. | 1/17/2024 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.12 - Standby power selection switch | 8.11.2.2.7 | x | Provide testing of the elevator emergency power selector switch. | 1/17/2024 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State Elevator Certificate. | 1/31/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.9 Cleaning of Car Tops | Clean the car top. | 1/31/2024 | ||
A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | During emergency power testing, car failed to recall to lobby. | 1/30/2024 | |
A17.1-2016 : Elevators | 4.12 - Standby power selection switch | 2.27.2 | x | Provide testing of the elevator emergency power selector switch in the lobby. | 1/30/2024 |