Inspection
Inspection Details
Equipment ID
18711
18711
Inspection Date
6/5/2024
6/5/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Bradley Rasnake
Bradley Rasnake
Mechanic Name
Walter Tauchert
Walter Tauchert
Relief Valve Pressure
480
480
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
22
22
External ID
dcc0b190-e1da-43f7-be07-e6fb351e54e9
dcc0b190-e1da-43f7-be07-e6fb351e54e9
Location
Chesterfield Business Parkway
100 Chesterfield Business Pkwy, Chesterfield, MO
Phone: (636) 728-5163
100 Chesterfield Business Pkwy, Chesterfield, MO
Phone: (636) 728-5163
Owner
Attn: Joshua M. Coffman
Land West #7 LLC c/o Trident Group
17998 Chesterfield Airport Rd, Ste 200, Chesterfield, MO 63005
Phone: (636) 449-2600 Ext: 12
Alt Phone: (314) 744-1661
Email: josh@ustrident.com
Land West #7 LLC c/o Trident Group
17998 Chesterfield Airport Rd, Ste 200, Chesterfield, MO 63005
Phone: (636) 449-2600 Ext: 12
Alt Phone: (314) 744-1661
Email: josh@ustrident.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | OSV is not sealed. Perform OSV test on or before next annual inspection. | 6/4/2021 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1001.2(a)(17) | Yes | No | Battery backup lowering unit not working correctly, repair/replace as needed. | 5/2/2023 |
| A17.1-1996 : Elevators | 2.36 - Hydraulic Cylinders | 302.3 | No | No | Provide pit bucket. | 2/20/2026 |
| A17.1-1996 : Elevators | 2.36 - Hydraulic Cylinders | 1004.2(b)(19) | No | No | Remove scavenger line from tank. | 2/20/2026 |
| A17.1-1996 : Elevators | 2.36 - Hydraulic Cylinders | 1004.2(b)(19) | No | No | Remove scavenger pump unit from pit. | 2/20/2026 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide MCP. | 2/20/2026 |
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | Yes | No | Unsealed. | 5/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | OSV is not sealed or tagged. Shall be tested within 30 days. | 2/20/2026 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 3.26.10 | Yes | No | Emergency lowering device shall be made operational. Re-inspection required | 6/17/2024 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | No | No | There shall be a switch in the disconnect that will not activate the emergency lowering device when the disconnect is turned off | 2/20/2026 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | Emergency lowering device is not working. Re-inspection required | 3/31/2025 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | Yes | No | There shall be a switch in the disconnect that will not activate the emergency lowering device when the disconnect is turned off. Re-inspection required | 3/31/2025 |
| A17.1-1996 : Elevators | 2.36 - Hydraulic Cylinders | 1004.2(b)(19) | Yes | No | Remove scavenger line from the tank. | 2/20/2026 |
| A17.1-1996 : Elevators | 2.36 - Hydraulic Cylinders | 1004.2(b)(19) | Yes | No | Remove scavenger unit from the pit. | 2/20/2026 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | Yes | No | Provide existing battery backup lowering unit to work properly. | 2/20/2026 |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(5) Oil Leakage Collection | No | No | Cylinder head packing is worn and leaking, repair as needed. | 2/20/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 3/13/2026 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | Yes | No | Provide existing battery backup lowering unit to work properly. | 4/6/2026 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | Yes | No | Provide existing battery backup lowering unit to work properly. |