Inspection
Inspection Details
Equipment ID
18753
18753
Inspection Date
6/3/2024
6/3/2024
Inspection Type
Major Alteration
Major Alteration
Inspector Name
Conde (Cache) Kinsella
Conde (Cache) Kinsella
Mechanic Name
Edward Bauer
Edward Bauer
Relief Valve Pressure
430
430
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
26
26
External ID
ac446b35-506c-40ea-afeb-55122d37b001
ac446b35-506c-40ea-afeb-55122d37b001
Location
Station Plaza- Bldg D
140 S Kirkwood Rd, Kirkwood, MO
Phone: (314) 775-2921
140 S Kirkwood Rd, Kirkwood, MO
Phone: (314) 775-2921
Owner
Attn: Maxus Properties - Kirkwood Station Plaza
Maxus Properties - Kirkwood Station Plaza
104 Armour Rd, N Kansas City, MO 64116
Phone: (314) 775-2921
Maxus Properties - Kirkwood Station Plaza
104 Armour Rd, N Kansas City, MO 64116
Phone: (314) 775-2921
Billing
Attn: Kirkwood Station Plaza Apartments
Kirkwood Station Plaza Apartments
141 E Madison Ave, Kirkwood, MO 63122
Phone: (314) 775-2921
Email: bdifani@maxusprop.com
Kirkwood Station Plaza Apartments
141 E Madison Ave, Kirkwood, MO 63122
Phone: (314) 775-2921
Email: bdifani@maxusprop.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | In cab emergency phone shall work. | 1/25/2019 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 11/14/2025 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Car missing cover for lights | 11/14/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | Replace the missing tile on the car floor. It is creating a tripping hazard. | 11/14/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | There is no operating certificate displayed in machine room. A current MO State operating certificate shall be displayed in the elevator machine room. | 11/14/2025 |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | Yes | No | The car door restrictor is not operating properly. Take corrective action. | 6/3/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Testing incomplete. Unable to run car onto stopring to complete pressure test. Need relief pressure and 15 min stand test to complete. | 12/2/2025 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work. | 12/2/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision place over it. | 12/2/2025 |
| A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 204.7 | No | No | Car top light shall be operational. | 12/2/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision place over it. | 5/12/2026 |
| A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 204.7 | No | No | Car top light shall be operational. | 5/12/2026 |