Inspection
Inspection Details
Equipment ID
11452
11452
Inspection Date
11/16/2018
11/16/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
Slide
Governor Rope Pull
NA
NA
Door Closing Force
24
24
External ID
bed3177f-fabb-498a-846d-eb7339b140ec
bed3177f-fabb-498a-846d-eb7339b140ec
Location
Bevo Bottling Plant- Bldg #137
619 ARSENAL ST, SAINT LOUIS, MO
619 ARSENAL ST, SAINT LOUIS, MO
Owner
Attn: Derik Schwaegel
Anheuser Busch
1 BUSCH PL 137-2, SAINT LOUIS, MO 63118
Phone: (314) 713-7504
Anheuser Busch
1 BUSCH PL 137-2, SAINT LOUIS, MO 63118
Phone: (314) 713-7504
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Shorten hoist ropes, negative cwt. runby and adjust tension between ropes. | 3/14/2019 |
| conversion | conversion | n/a | No | No | Replace interlock box cover at level 5. | 3/14/2019 |
| conversion | conversion | n/a | No | No | Replace cap bolt on pick-up roller at level 4. | 3/14/2019 |
| conversion | conversion | n/a | No | No | Replace sight guard on right hoistway door at level B. | 3/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.28 - Counterweight and counterweight buffer | 2.21 | No | No | Repair or replace counterweight sheave. Rope imprinting sheave groove. | 9/26/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Water in the pit. | 9/26/2025 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | Yes | Suspension ropes are severely undersized with rouge. Red tagged, Re-inspection required | 10/28/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Right car top sheave bearing is going out causing a popping sound. Sheave tracks are also worn down causing ropes to sink into sheave grooves. | 9/26/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | There are numerous missing Fire tabs throughout hoistway, need to be replaced. | 9/26/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | The main traction sheave tracks are worn down causing the ropes to sink into sheave grooves. | 9/26/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | There are numerous fire tabs on hoistway doors missing | 9/26/2025 |
| A17.1-2016 : Elevators | 3.17 - Door and gate equipment | 8.6.4.13 | No | No | Hoistway door panels shall have 2 gibs mounted on the bottom of each panel | 9/26/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | There are numerous fire tabs on hoistway doors missing | 9/26/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 8.6.4.13 Door Systems | Yes | No | Basement hoistway doors shall be adjusted so that they are closed at the bottom of the door. Re-inspection required | 9/26/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.7 - Car door or gate | 2.14.5 | No | No | Car doors open too far and create a shear and pinch point. | 9/26/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Yes | No | Car top sheave bearings noisy, replace. |