Inspection
Inspection Details
Equipment ID
19206
19206
Inspection Date
11/15/2018
11/15/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Dawes
Robert Dawes
Mechanic Name
Timothy Driver
Timothy Driver
Relief Valve Pressure
Slide
Governor Rope Pull
0
0
Door Closing Force
20
20
External ID
b07c2eb4-9c6f-4634-bddf-c765c9565ec2
b07c2eb4-9c6f-4634-bddf-c765c9565ec2
Location
Nevada High School
800 W HICKORY ST, NEVADA, MO
800 W HICKORY ST, NEVADA, MO
Owner
Attn: UNK
Nevada R-5 School District
811 W HICKORY ST, NEVADA, MO 64772
Phone: (000) 000-0000
Email: mhendrix@nevada.k12.mo.us
Nevada R-5 School District
811 W HICKORY ST, NEVADA, MO 64772
Phone: (000) 000-0000
Email: mhendrix@nevada.k12.mo.us
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone not working Rule 1902.6 | 1/10/2019 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | Yes | Yes | Need to have a fire service log on site. Need to correct in 30 days. | 4/27/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 8.6.1.4 Need maintenance records onsite. | 2/20/2024 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No On-site Maintenance Records | 7/20/2023 |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | No | No | Machine room door not self closing | 7/20/2023 |
| A17.1-1996 : Elevators | 2.17 - Drive machine brake | 1002.3d | Yes | No | The emergency brake cable needs to be repaired (cable not attached to emergency brake handle). | 1/27/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone not working (Getting a busy signal). | 11/16/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No MCP on site (violation from last year). | 7/20/2023 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No on site documentation, no Maintenance log, no call back log, no fire service log. (violation from last year) | 7/20/2023 |
| A17.1-1996 : Elevators | 2.4 - Machine space | 100.3d | No | No | machine room needs to be self closing (violation from last year). | 7/20/2023 |
| A17.1-1996 : Elevators | 2.17 - Drive machine brake | 1002.3d | Yes | No | The emergency brake cable needs to be repaired (cable not attached to emergency brake handle). (Violation from last year) | 11/16/2022 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No current operating certificate. (Have not had a current one for 2 years) | 7/20/2023 |
| A17.1-1996 : Elevators | 1.7 - Car door or gate | 204.5 | No | No | Car Door damaged and does not meet code 204.5g(6). | 7/20/2023 |
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 204 | No | No | Car enclosure by car door damaged and does not meet code 204.1c | 7/20/2023 |
| A17.1-1996 : Elevators | 2.17 - Drive machine brake | 210.8 | Yes | No | The emergency brake cable needs to be repaired (cable not attached to emergency brake handle). (Violation from last year) | 2/20/2024 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No current operating certificate. (Have not had a current one for 2 years) | 2/21/2024 |
| A17.1-1996 : Elevators | 1.7 - Car door or gate | 204.5 | Yes | No | Car Door damaged and does not meet code 204.5g(6). | 2/20/2024 |
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 204 | Yes | No | Car enclosure by car door damaged and does not meet code 204.1c | 2/20/2024 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Yes | No | No MCP on site (violation from last year). | 2/20/2024 |
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.1 | No | No | Electrical boxes in machine space needs covers. | 2/21/2024 |
| A17.1-1996 : Elevators | 4.8 - Hoistway enclosure | 100.1 | No | No | Exhaust vent in hoistway needs a protective assembly (dampener) attached to complete fire rating. | 2/21/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No on-site documentation accessible for review. | 2/2/2024 |