Inspection
Inspection Details
Equipment ID
13732
13732
Inspection Date
7/8/2024
7/8/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Jake Brennan
Jake Brennan
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
83344193-6125-4a55-9494-1e601222f19c
83344193-6125-4a55-9494-1e601222f19c
Location
Fashion Square Lofts
1307 Washington Ave, St. Louis, MO
Phone: (314) 621-6262
1307 Washington Ave, St. Louis, MO
Phone: (314) 621-6262
Owner
Attn: Fashion Square Lofts
Fashion Square Lofts LLC
4439 Old Alton Rd, Granite City, IL 62040
Phone: (314) 621-9292
Fashion Square Lofts LLC
4439 Old Alton Rd, Granite City, IL 62040
Phone: (314) 621-9292
Billing
Attn: Fashion Square Lofts
Fashion Square Lofts LLC
1307 Washington Ave, St. Louis, MO 63103
Phone: (314) 621-9292
Email: fashionsquaremgr@cushwake.com
Fashion Square Lofts LLC
1307 Washington Ave, St. Louis, MO 63103
Phone: (314) 621-9292
Email: fashionsquaremgr@cushwake.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | All the on site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 1/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | An ABC type fire extinguisher with a current test tag shall be mounted convenient to the machine room door. | 1/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | No | No | The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | 1/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 2/28/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 2.18.5 | No | No | The governor rope shall be tagged. | 2/28/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | Yes | No | 8.11.2.1.2(gg) - Access to the winding drum safety shall be restored, and the safeties shall be tested with no load in the car. The means of access has been blocked by a new ceramic tile floor. The car/counterweight balance shall be verified and adjusted to the manufacturers specifications. | 2/28/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone fails to establish two way communication | 3/8/2022 |
| A17.1-2016 : Elevators | 2.29 - Car and counterweight safeties | 8.6.4.19.2 | Yes | Yes | Unable to perform annual test on car safeties. Flooring installed in car preventing access to wind up safety drum | 3/8/2022 |
| A17.1-2016 : Elevators | 3.28 - Counterweight and counterweight buffer | 8.11.2.1.3(m) | No | No | Replace deteriorated roller on the bottom left of the counter weight frame | 1/12/2026 |
| A17.1-2016 : Elevators | 3.22 - Wire rope fastening and hitch plate | 8.6.5.16.3 | Yes | No | Replace broken spring on counter weight rope hitch plate fastening | 2/27/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Yes | No | Replace broken spring on the counter weight rope shackle rod. | 7/8/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Phone in car fails to establish two-way communication | 7/8/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace the worn counter weight roller on the top left side of the counter weight | 1/12/2026 |