Inspection
Inspection Details
Equipment ID
6936
6936
Inspection Date
11/9/2018
11/9/2018
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Jeffrey Krug
Jeffrey Krug
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
Slide
8 in
8 in
Governor Rope Pull
45/810
45/810
Door Closing Force
12
12
External ID
76b9d0a3-6e72-4ce9-b7a1-c4f26395f74d
76b9d0a3-6e72-4ce9-b7a1-c4f26395f74d
Location
Mark Twain Hotel
205 N 9TH ST, SAINT LOUIS, MO
205 N 9TH ST, SAINT LOUIS, MO
Owner
Mark Twain Hotel Partners LP
205 N 9TH ST, SAINT LOUIS, MO 63101-1416
205 N 9TH ST, SAINT LOUIS, MO 63101-1416
Billing
Attn: Mark Twain Hotel Partners LP
205 N 9TH ST, SAINT LOUIS, MO 63101-1416
205 N 9TH ST, SAINT LOUIS, MO 63101-1416
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Door restrictor doesn't work | 2/24/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not dial out | 9/26/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Excessive amount of debris and trash in pit | 9/26/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Phone in car fails to establish two-way communication (Busy Signal) | 9/12/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Lights in elevator cab shall be guarded to prevent breakage | 10/8/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Testing incomplete. Need to complete annual and category 5 test. Only tested emergency phone, bell, and light. | 10/8/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | Yes | After entering the car top it was discovered the hoist ropes and governor rope failed the gauge test. Hoist rope and governor rope shall be replaced. Elevator Red Tagged. | 10/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | Yes | Emergency phone is not operational since 2022. Elevator Red Tagged. | 10/8/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The category 5 portion of the required tested was completed at the time of the hoist/governor rope replacement inspection. The category 1/annual testing items shall be witnessed to complete the annual inspection. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone has no been working since 2022 was not working still at time of hoist/governor rope replacement inspection. The phone shall be made operational by 10/10/25 or the elevator will be red tagged again. |