Inspection
Inspection Details
Equipment ID
6935
6935
Inspection Date
11/9/2018
11/9/2018
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Jeffrey Krug
Jeffrey Krug
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
Slide
10 in
10 in
Governor Rope Pull
200/400
200/400
Door Closing Force
17
17
External ID
8749449f-fef6-4730-b7ca-0bdff6fe13ba
8749449f-fef6-4730-b7ca-0bdff6fe13ba
Location
Mark Twain Hotel
205 N 9TH ST, SAINT LOUIS, MO
205 N 9TH ST, SAINT LOUIS, MO
Owner
Mark Twain Hotel Partners LP
205 N 9TH ST, SAINT LOUIS, MO 63101-1416
205 N 9TH ST, SAINT LOUIS, MO 63101-1416
Billing
Attn: Mark Twain Hotel Partners LP
205 N 9TH ST, SAINT LOUIS, MO 63101-1416
205 N 9TH ST, SAINT LOUIS, MO 63101-1416
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Will not reset when Phase I is turned off | 11/9/2018 |
| conversion | conversion | n/a | No | No | Repair machine room door to be self closing and locking | 2/24/2021 |
| conversion | conversion | conversion - reinspect | Yes | No | Doors don't stay open on Phase II fire service when car is at another floor | 11/9/2018 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Phase II fire service - Doors don't stay open when car is at another floor | 12/5/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Phase II fire service - "HOLD'' doesn't work | 12/5/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)12 (Door open zones) | Yes | No | Door restrictor doesn't work | 12/5/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Doors stay open at floors during Phase II operation. | 12/13/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not dial out | 9/26/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Excessive amount of debris and trash in pit | 6/5/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Phone in car fails to establish two-way communication (Busy Signal) | 9/12/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Yes | No | The suspension ropes need to seat to the same depth in the drive sheave grooves. Two of the ropes are sitting lower in the grooves of the drive sheave. | 9/12/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | Yes | Unable to finish category 5 full load test. Unit failed to pick capacity. Elevator Red Tagged | 9/18/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | Yes | Emergency phone is not operational since 2022. Elevator Red Tagged. | 9/18/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | A slide measurement shall be obtained. Unable to test due to car being unable to pick capacity. | 9/18/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Yes | No | The suspension ropes need to seat to the same depth in the drive sheave grooves. Two of the ropes are sitting lower in the grooves of the drive sheave. Note: This violation was cited during an alteration inspection on 5/22/2024 and is still not corrected. | 9/18/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency communications/phone is car shall be operational. This violation shall be corrected within 14 days. | 11/13/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 6/5/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2 On-Site Documentation | No | No | A current MCP shall be provided in the machine room including maintenance, repair, testing and fire service testing logs. | 6/5/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall be operational. | |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Yes | No | Pit light shall work. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self closing, self locking, and shall be operable from the interior space without a key. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Excessive amount of debris and trash in the pit shall be cleaned. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A current MCP shall be provided in the machine room including maintenance, repair, testing and fire service testing logs. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A current MCP shall be provided in the machine room including maintenance, repair, testing and fire service testing logs. |