Inspection
Inspection Details
Equipment ID
503
503
Inspection Date
5/22/2024
5/22/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Bradley Rasnake
Bradley Rasnake
Mechanic Name
Ronald Hogue, Jr
Ronald Hogue, Jr
Relief Valve Pressure
500
500
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
25
25
External ID
898252f7-9da2-4e04-9fd2-b5f4e1d53053
898252f7-9da2-4e04-9fd2-b5f4e1d53053
Location
Wilson's Structural Steel LLC
2455 Cassens Dr, Fenton, MO
Phone: (636) 343-4777
2455 Cassens Dr, Fenton, MO
Phone: (636) 343-4777
Owner
Attn: Wilson's Structural Steel LLC
Wilson's Structural Steel LLC
2455 Cassens Dr, Fenton, MO 63026
Phone: (000) 000-0000
Email: jng@wilsonsstructuralsteel.com
Wilson's Structural Steel LLC
2455 Cassens Dr, Fenton, MO 63026
Phone: (000) 000-0000
Email: jng@wilsonsstructuralsteel.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Need maintenance control Program | 6/12/2019 | ||
conversion | conversion | n/a | Pit shall be clean and dry. | 6/12/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept clean and dry | 6/12/2019 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No MCP - provide maintenance records. | 7/27/2020 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Clean water in pit. Needs to be dry. | 7/27/2020 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Ceiling panels in car are of open egg crate type, which provide no protention for passengers in event of breakage. Replace with solid type panels or cover tubes with plastic sleeves. | 5/18/2021 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept clean and dry. Remove water from pit. | 5/18/2021 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be clean and dry. | 6/15/2022 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | 2 way communication not working | 5/22/2024 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency phone shall be made operational. Re-inspection required | 5/22/2024 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit needs to be kept clean & dry | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Nothing other than elevator equipment shall be stored in the elevator equipment room | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Lighting in the machine room shall be corrected | |||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency phone shall be made operational. Re-inspection required | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the machine room | |||
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept clean & dry |