Inspection
Inspection Details
Equipment ID
17076
17076
Inspection Date
10/19/2018
10/19/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
John Ryan
John Ryan
Mechanic Name
Scott Tiemann
Scott Tiemann
Relief Valve Pressure
430
430
Slide
Governor Rope Pull
Door Closing Force
22
22
External ID
a8868892-4887-452e-9efd-7ffc8c29cc02
a8868892-4887-452e-9efd-7ffc8c29cc02
Location
Chai Apartments
6 MILLSTONE CAMPUS DR, SAINT LOUIS, MO
6 MILLSTONE CAMPUS DR, SAINT LOUIS, MO
Owner
Community Housing Asociation Inc
8 MILLSTONE CAMPUS DR STE 2000, SAINT LOUIS, MO 63146-6604
8 MILLSTONE CAMPUS DR STE 2000, SAINT LOUIS, MO 63146-6604
Billing
Attn: Community Housing Management Corp
8 MILLSTONE CAMPUS DR STE 2000, SAINT LOUIS, MO 63146-6604
8 MILLSTONE CAMPUS DR STE 2000, SAINT LOUIS, MO 63146-6604
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 4/12/2022 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 4/12/2022 |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | No | No | Oil leakage collected from the cylinder packing gland and cylinder head shall not exceed 5 gallons before removal. A written record shall be kept of the quantity of hydraulic fluid added to the system and emptied from leakage collection containers and pans, shall not exceed 5 gal before removal, shall be covered, and shall not be permitted to overflow. | 4/12/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required shall be provided in the machine room. Fire service testing shall be documented monthly. No 2023 log present. | 12/11/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 12/11/2023 |
| A17.1-1996 : Elevators | 2.4 - Machine space | 101.1a | No | No | Fix the leak in machine room ceiling. | 12/20/2024 |
| A17.1-1996 : Elevators | 1.7 - Car door or gate | 204.4 | Yes | No | Car door restrictor shall work at all floors, car door flapper missing. | 4/30/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell shall work with loss of main 120v power. | 4/30/2026 |
| A17.1-1996 : Elevators | 2.4 - Machine space | 100.3d | No | No | Machine room ceiling tiles missing/damaged. Replace. | 4/30/2026 |
| A17.1-1996 : Elevators | 2.4 - Machine space | 100.3d | No | No | 4X4 Electrical box in machine room needs to have wiring inside box and cover installed. (Fire alarm box and telecom box) | 4/30/2026 |