Inspection
Inspection Details
Equipment ID
1463
1463
Inspection Date
6/25/2024
6/25/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Matthew Moon
Matthew Moon
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
22
22
External ID
dbe02f12-69aa-43ac-9a07-44431605708f
dbe02f12-69aa-43ac-9a07-44431605708f
Location
Centene Place A
7711 Carondelet Ave, Clayton, MO
Phone: (314) 565-2824
Alt Phone: (314) 721-8427
Fax: (314) 721-8533
7711 Carondelet Ave, Clayton, MO
Phone: (314) 565-2824
Alt Phone: (314) 721-8427
Fax: (314) 721-8533
Owner
Attn: Property Manager
Centene Plaza c/o Rafco Properties
7700 Forsyth Blvd, Ste 100, Clayton, MO 63105
Phone: (314) 721-8427
Email: ONSITE@RAFCOPROP.COM
Centene Plaza c/o Rafco Properties
7700 Forsyth Blvd, Ste 100, Clayton, MO 63105
Phone: (314) 721-8427
Email: ONSITE@RAFCOPROP.COM
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State operating certificate in machine room | 7/8/2020 | ||
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | All the on site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 10/6/2025 | ||
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1001.2(a)(17) | x | The emergency/standby power operation of the elevator shall be tested. | 2/18/2022 | |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | x | Fire service operation shall be tested. | 2/18/2022 | |
| A17.1-1996 : Elevators | 2.11 - Disconnecting Means and Control | 210.4 | The 120VAC car lighting branch circuit shall not supply the recently installed in-car information displays. | 10/6/2025 | ||
| A17.1-1996 : Elevators | 2.9 - Guarding of exposed auxiliary equipment | 104.1 | Kick angles shall be installed around the machine room cable slots to keep items from falling into the hoistway. | 10/6/2025 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | A category 5 test shall be performed. | 2/18/2022 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | This elevator is overdue for a full load test. A category 5 test shall be performed and witnessed. | 3/5/2022 | |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1001.2(a)(17) | x | Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator. | 3/5/2022 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Fire service shall be tested to complete the annual inspection. | 3/5/2022 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | This elevator is overdue for a full load test. A category 5 test shall be performed and witnessed. | 9/21/2022 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Fire service shall be tested to complete the annual inspection. | 9/21/2022 | |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post a current MO State operating certificate in the elevator machine room. | 10/6/2025 |