Inspection
Inspection Details
Equipment ID
13817
13817
Inspection Date
7/29/2024
7/29/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Melvin Barks Jr.
Melvin Barks Jr.
Mechanic Name
Relief Valve Pressure
N/A
N/A
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
fb645bcd-ac07-4bde-a7c0-830dad21c195
fb645bcd-ac07-4bde-a7c0-830dad21c195
Location
St. Francois County Courthouse
1 N Washington St, Farmington, MO
Phone: (573) 756-3623
1 N Washington St, Farmington, MO
Phone: (573) 756-3623
Owner
Attn: St. Francois County Courthouse
St. Francois County Courthouse
1 N Washington St, Farmington, MO 63640
Phone: (573) 631-8039
Email: bbriley@sfcgov.org
St. Francois County Courthouse
1 N Washington St, Farmington, MO 63640
Phone: (573) 631-8039
Email: bbriley@sfcgov.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | 1) Maintenance records shall document compliance with 8.6 of the Code and shall include records on the all activities. | 7/1/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 1) The following documents specified in 8.6.1.2.2(a), (b), and (c) shall be written and permanently kept on-site in the machine room, machinery space, control room, control space in hard copy for each unit for elevator personnel. (b) Procedures for inspections and tests are not on site. Ref: 8.6.1.2.2 | 7/1/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | 2) Installation of electrical equipment and wiring shall conform to NFPA 70. Traveling cables shall be supported as per article 620.41. Ref: 2.8.2.1 | 7/1/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | 3) Installation of electrical equipment and wiring shall conform to NFPA 70. Traveling cables shall be ran in a raceway, 6 ft. from first point of support on the hoistway wall as per article 620.44(b). Ref: 2.8.2.1 | 7/1/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) | No | No | Incomplete maintenance control program procedures for inspections and test are not on-site. | 4/20/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | OSV five (5) year test due at next inspection. | 4/20/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No current operating certificate. | 4/26/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light failed to operate when 110 disconnected. | 7/29/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Standing water in pit. Pit shall be kept clean and dry. | 8/27/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone failed to operate during test. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light failed when 110 disconnected. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency bell failed. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | Basement level lobby flooring threshold at elevator exit causing a tripping hazard. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | Basement level lobby flooring threshold at elevator exit causing a tripping hazard. |