Inspection
Inspection Details
Equipment ID
18095
18095
Inspection Date
11/21/2018
11/21/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Clyde Johnson
Clyde Johnson
Mechanic Name
William Gorden, Jr.
William Gorden, Jr.
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
282cfe32-47cf-49b4-84f1-6897655c48ff
282cfe32-47cf-49b4-84f1-6897655c48ff
Location
America's Center
701 CONVENTION PLZ, SAINT LOUIS, MO
701 CONVENTION PLZ, SAINT LOUIS, MO
Owner
America's Center
701 CONVENTION PLZ, SAINT LOUIS, MO 63101-1275
701 CONVENTION PLZ, SAINT LOUIS, MO 63101-1275
Billing
Attn: America's Center
701 CONVENTION PLZ, SAINT LOUIS, MO 63101-1275
701 CONVENTION PLZ, SAINT LOUIS, MO 63101-1275
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.2.13 | No | No | Both handrails have cracks and need to be replaced. Reinspection required. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | Pits need cleaning. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.2.13 | No | No | Both handrails have cracks and need to be replaced. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.19 - Maintenance records | 8.6.1.4 | No | No | Provide written maintenance records to be kept on site. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.1 (c) | No | No | Cracks in handrail,replace | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.19 - Maintenance records | 8.6.1.4 | No | No | Provide MCP | 3/18/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide comb impact test | 4/5/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | No | No | Upper pit light not working | 4/5/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.6.8.1 | No | No | The right and left side handrails have degraded and shall be replaced. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.7 - Combplate and comb step impact device | 8.6.8.4 Combplates | No | No | Comb plate is missing one tooth. Replace comb plate. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.2.13 | Yes | No | Both handrails have cracks and need to be replaced. Reinspection required. |