Inspection
Inspection Details
Equipment ID
21239
21239
Inspection Date
8/29/2024
8/29/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Brett Garmon
Brett Garmon
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
Na
Na
External ID
bdcda58c-08f2-4ad7-873a-5d29fcdf23ac
bdcda58c-08f2-4ad7-873a-5d29fcdf23ac
Location
Dierberg's
1080 Lindemann Rd, St. Louis, MO
Phone: (636) 532-8884
1080 Lindemann Rd, St. Louis, MO
Phone: (636) 532-8884
Owner
Attn: Karen Schrader
Dierberg General Office
16690 Swingley Ridge Rd, Chesterfield, MO 63017
Phone: (636) 812-1359
Email: SchraderK@dierbergs.com
Dierberg General Office
16690 Swingley Ridge Rd, Chesterfield, MO 63017
Phone: (636) 812-1359
Email: SchraderK@dierbergs.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | A comb plate has a broken tooth and shall be replaced. | 10/11/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.5 Escalator Skirt Panels | No | No | Test not complete - no indexing | 10/11/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 8.6.8.6 | Yes | No | Replace three broken step treads. | 9/23/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.2 - Stop switch | 8.11.4.2.2 | Yes | No | Replace cover on upper landing stop switch. | 9/23/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 6.1.3.4 (Hand rails) (Re-Inspection) | No | No | Handrails cracking. Shall be replaced | 3/9/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3 Step/Skirt Performance Index | Yes | No | Step indexing incomplete. Shall finish step indexing test and brake torque test | 12/1/2021 |
| A17.1-1996 : Escalators | 7.10 - Operating and safety devices | 805.3a | No | No | Escalator shall have a clear plastic cover over emergency stop switches with an audible alarm which is activated by lifting the cover | 7/8/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.10 - Operating and safety devices | 6.1.6.3.1 Emergency Stop Buttons (Re-Inspection) | Yes | No | Escalators shall have a clear plastic cover over emergency stop switches with an audible alarm which is activated by lifting the cover. Re-inspection required | 12/7/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.11 - Skirt obstruction device | 6.1.6.3.6 | Yes | No | Bottom left skirt switch does not work, needs repaired. Re-inspection required | 8/7/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.7 - Combplate and comb step impact device | 6.1.6.3.13 | Yes | No | Bottom left comb impact device could not be adjusted within specifications, needs repaired. Re-inspection required | 8/7/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Temporary inspection run station operates unit backward, needs repaired. Re-inspection required | 8/7/2026 |