Inspection
Inspection Details
Equipment ID
15718
15718
Inspection Date
8/20/2024
8/20/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Benjamin Williams
Benjamin Williams
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
19
19
External ID
d477b929-9313-4be9-89af-1196eb5bb748
d477b929-9313-4be9-89af-1196eb5bb748
Location
Peper Lofts
701 N 1st St, St. Louis, MO
Phone: (314) 260-9266
Email: bwright@advantesgrp.com
701 N 1st St, St. Louis, MO
Phone: (314) 260-9266
Email: bwright@advantesgrp.com
Owner
Attn: Jasmina Hozbo
Peper Lofts
701 N 1st St, Ste 102, St. Louis, MO 63102
Phone: (314) 260-9266
Alt Phone: (314) 574-9321
Email: accountspayable@advantesgrp.com
Peper Lofts
701 N 1st St, Ste 102, St. Louis, MO 63102
Phone: (314) 260-9266
Alt Phone: (314) 574-9321
Email: accountspayable@advantesgrp.com
Billing
Attn: Alan Luffy
Peper Lofts
701 N 1st St, Ste 102, St. Louis, MO 63102
Phone: (314) 474-0528
Alt Phone: (314) 788-3220
Email: accountspayable@advantesgrp.com
Peper Lofts
701 N 1st St, Ste 102, St. Louis, MO 63102
Phone: (314) 474-0528
Alt Phone: (314) 788-3220
Email: accountspayable@advantesgrp.com
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Car door restrictor does not work and shall be repaired. | 1/4/2019 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Car top light does not work and shall be repaired. | 1/4/2019 | ||
MO Minimum : Elevators | (A) - Hoistways | (A)16 | High voltage (110V) wiring on car top shall be enclosed in conduit. | 1/4/2019 | ||
MO Minimum : Elevators | (A) - Hoistways | (A)16 | Hoistway duct covers shall be installed. | 1/4/2019 | ||
MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | Suspension rope data tags shall be installed. | 1/4/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light does not work and shall be repaired. | 1/4/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)8 | Pit sump pump cover shall be installed flush with the pit floor. | 1/4/2019 | ||
MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | x | x | Weight related testing of safeties, buffers, and machine brakes shall be completed. | 11/8/2018 |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | The door restrictor shall be operational. | 9/22/2020 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current state operating certificate shall be posted in the machine room in a non-combustible frame. | 10/27/2020 | ||
MO Minimum : Elevators | (I) - Pits | (I)3 | A counterweight guard shall be installed. | 10/27/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The in car emergency light shall be operational. | 9/22/2020 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The alarm bell shall operate on auxiliary power. | 9/22/2020 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The in car emergency telephone shall be operational. | 9/22/2020 | |
MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | x | x | Fire service phase 1 instructions shall be posted at the hall key switch, and fire service phase 2 instructions shall be posted in the car. | 9/22/2020 |
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Fire service phase 1 & phase 2 key switches shall be legible. | 9/22/2020 |
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | The 3rd landing car call shall be operational on fire service phase 2. | 9/22/2020 |
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room door shall be self-locking and self-closing. | 10/27/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | The machine room fire extinguisher shall be tagged to verify that the extinguisher is current. | 10/27/2020 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | Traveling cables in the machine room shall be enclosed in wireway. | 10/27/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | A code data plate is required. | 10/27/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 12/1/2021 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.11 Runby (Re-Inspection) | x | Provide code compliant counterweight runby. | 8/22/2023 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Testing is incomplete. Full load buffer testing, setting the safeties, and no load counterweight buffer test still need to be completed. | 8/23/2023 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | A current ABC type fire extinguisher shall be provided in the machine room. |