Inspection
Inspection Details
Equipment ID
3393
3393
Inspection Date
9/24/2024
9/24/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Glenn Everhart
Glenn Everhart
Mechanic Name
Michael Collumbien
Michael Collumbien
Relief Valve Pressure
480
480
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
28
28
External ID
5ce6ab91-fff8-4462-be2d-e6139b8b1a28
5ce6ab91-fff8-4462-be2d-e6139b8b1a28
Location
Benton Square
E 6th St at N Walnut St, Rolla, MO
Phone: (573) 468-3141
E 6th St at N Walnut St, Rolla, MO
Phone: (573) 468-3141
Owner
Attn: Dominic DeLuca
KACE Properties
PO Box 132, St. James, MO 65559
Phone: (573) 263-1033
Email: dominic.deluca@mypcb.com
KACE Properties
PO Box 132, St. James, MO 65559
Phone: (573) 263-1033
Email: dominic.deluca@mypcb.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | oil/water in pit | 7/8/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | water/oil in pit | 7/8/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | oil in pit--elevator needs to have new packings install | 7/8/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | oil in pit--clean--repack | 7/28/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Oil in pit- clean | 12/13/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher in machine room is out of date | 2/14/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.35 - Supply Line and Shutoff Valve | 3.19 | No | No | Overspeed valve has seal but not dated. Needs to be tested unless a proper date can be confirmed | 2/14/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine door does self close but can be left in unlocked position. Needs to only able to open from outside by a key | 2/14/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone not working | 2/14/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Sump pump piping runs directly over elevator machine & controller piping is not guarded or guttered. | 9/15/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone failed to operate appears phone line has been removed. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Light does not give off enough illumination to provide the required lighting at floor lever in front of controller. | 9/15/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Lighting in machine room is hanging from the ceiling, secured only by wire nuts. | 9/15/2025 |