Inspection
Inspection Details
Equipment ID
13661
13661
Inspection Date
9/5/2024
9/5/2024
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Kevin Hecht
Kevin Hecht
Mechanic Name
Christian Schickedanz
Christian Schickedanz
Relief Valve Pressure
NA
NA
Slide
TBD
TBD
Governor Rope Pull
TBD
TBD
Door Closing Force
TBD
TBD
External ID
5516fd63-9570-44f4-a88f-5272c559d05b
5516fd63-9570-44f4-a88f-5272c559d05b
Location
Kiener East Garage
500 Pine St, St. Louis, MO
Phone: (314) 241-4262
Email: jonthan.britton@intpark.com
500 Pine St, St. Louis, MO
Phone: (314) 241-4262
Email: jonthan.britton@intpark.com
Owner
Attn: Inter Park Holdings LLC
Inter Park Holdings LLC
100 S 9th St, St. Louis, MO 63102
Phone: (000) 000-0000
Inter Park Holdings LLC
100 S 9th St, St. Louis, MO 63102
Phone: (000) 000-0000
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Car top needs to be cleaned. | 1/15/2021 | ||
conversion | conversion | conversion - reinspect | x | Door close operation shall require constant pressure on phase 2 fire service. | 10/1/2018 | |
conversion | conversion | conversion - reinspect | x | Phase 2 fire service switch in car shall be keyed alike with other fire service switches. | 10/1/2018 | |
conversion | conversion | conversion - reinspect | x | Return to phase 1 fire service did not work when turning phase 2 switch to off. | 10/1/2018 | |
conversion | conversion | n/a | Need fire fighters instructions in main lobby. | 1/15/2021 | ||
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | Phase 1 & Phase 2 key switches shall be keyed the same. | 10/3/2019 | |
MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)7 | x | x | Provide missing seal on the governor. | 10/3/2019 |
MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | x | x | A category 5 inspection is required. | 10/3/2019 |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/15/2021 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | The lighting in the stairwell that leads to the machine room shall be operational. | 12/8/2021 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | A code compliant MCP and all the on-site documentation required shall be provided in the machine room. | |||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The remainder of the annual and category 5 test needs to be completed. The inspection could not be completed due to testing problems on the other elevator being red tagged and removed from service. Note: The hoistway, hoistway door interlocks, gate switch and restrictor, and fire service have been inspected. | 10/22/2024 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Governor overspeed, governor pull out/pull through, safety test and slide, car buffer, and counterweight buffer must be tested to complete category 5 test. | 12/5/2024 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Counterweight buffer and governor pullout/pull thru must still be tested to complete category 5 testing. |