Inspection
Inspection Details
Equipment ID
18544
18544
Inspection Date
9/12/2024
9/12/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
James Bishop
James Bishop
Relief Valve Pressure
520
520
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
23
23
External ID
aaeb94ca-1958-41cd-b5a9-fe173eaa768c
aaeb94ca-1958-41cd-b5a9-fe173eaa768c
Location
Northwest Airport Inn
3570 N Lindbergh, St. Ann, MO
Phone: (314) 291-4940
3570 N Lindbergh, St. Ann, MO
Phone: (314) 291-4940
Owner
Attn: Northwest Airport Inn
Northwest Airport Inn
3570 N Lindbergh Blvd, St. Ann, MO 63074
Phone: (314) 291-4940
Email: john@northwestairportinn.com
Northwest Airport Inn
3570 N Lindbergh Blvd, St. Ann, MO 63074
Phone: (314) 291-4940
Email: john@northwestairportinn.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | Pit light shall work. | 12/3/2018 | ||
A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | The cylinder packing is leaky and shall be monitored. | 10/1/2019 | ||
A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 10/7/2021 | ||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | 10/7/2021 | ||
A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 1001.2(c)(18) | All electrical wiring in the hoistway shall be enclosed in metal conduit, flexible conduit, or metal raceway, or be in compliance with NFPA 70. | 10/7/2021 | ||
A17.1-1996 : Elevators | 2.4 - Machine space | 1001.2(b)(4) | The elevator machine and control equipment shall be located in a separate room or separated space designed as an elevator machine room or space and shall be accessible only to authorized personnel. | 10/7/2021 | ||
A17.1-1996 : Elevators | 3.10 - Hoistway construction | 1001.2(c)(16) | Patch holes in the hoistway walls. | 10/7/2021 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Two-way communication device shall work (with and without main power) and give proper location. | 11/8/2023 | |
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | Emergency lighting shall work. | 11/8/2023 | |
A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | Machine room door shall be self-closing and self-locking. | 11/20/2023 | ||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 11/20/2023 | ||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | The pit shall be kept clean. Remove excess debris. | 11/20/2023 | ||
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2c (Clean Car Tops) | Clean top of car. | 11/20/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Replace missing 2x4 electrical box cover on car top. | 11/20/2023 | ||
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | Non-elevator related items shall not be stored in machine room (heaters, buckets, water shutoff key, etc). | 11/20/2023 | ||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 11/20/2023 | ||
A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | The machine room door shall be self-closing and self-locking and shall be operable from the interior space without the use of a key. The door is not self-closing. | 11/20/2023 |