Inspection
Inspection Details
Equipment ID
5724
5724
Inspection Date
8/13/2024
8/13/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Clifford Miller
Clifford Miller
Relief Valve Pressure
440
440
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
20
20
External ID
f4d9f7e0-ee43-4d46-9bb2-2d975b2e20db
f4d9f7e0-ee43-4d46-9bb2-2d975b2e20db
Location
Friendship Manor
917 NW Summit St, Blue Springs, MO
Phone: (816) 228-5400
917 NW Summit St, Blue Springs, MO
Phone: (816) 228-5400
Owner
Attn: Friendship Manor
Friendship Manor
917 NW Summit St, Blue Springs, MO 64015
Phone: (000) 000-0000
Email: 0622@nationalchurchresidences.org
Friendship Manor
917 NW Summit St, Blue Springs, MO 64015
Phone: (000) 000-0000
Email: 0622@nationalchurchresidences.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | packing gland is leaking excessively, 5 gallon pit bucket overflows between maintenance visits, install new packing gland | 8/6/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | clean up the pit, hydraulic oil all over the pit floor | 8/6/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | monthly fire service test log was not posted in the machine room | 8/6/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | the crosshead data plate has the capacity as 2100, the car operating panel has the capacity as 2500, the capacity on the data tag on the tank in the machine room is 2500. put the correct capacity of 2500 on the crosshead data tag | 8/18/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(c) On-Site Maintenance Records (Other Records) | No | No | A record of findings for firefighters’ service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be kept in the machine room. | 8/18/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | display the current copy of the state operating certificate in the elevator machine room and update it annually when received from the state, the certificate in the machine room expired in 2015 | 8/18/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display the current copy of the state operating certificate in the machine room, the one in the certificate frame expired in 2015 | 10/10/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | The Monthly fire service test log in the machine room is not being filled out does not have any entries for 2024 on the log | 10/10/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | No | Battery lowering unit batteries are dead, replace batteries (3.26.10) | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the Pit | |
| MO Minimum : Elevators | (S) - Fire Service | 211.3a(8) Visual and audible signal | Yes | No | Fire service Phase 1 audible signal did not work, repair audible signal for Fire service |