Inspection
Inspection Details
Equipment ID
5723
5723
Inspection Date
8/13/2024
8/13/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Clifford Miller
Clifford Miller
Relief Valve Pressure
400
400
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
26
26
External ID
d51ecb59-82c4-484c-a18d-40bb8ebc0f26
d51ecb59-82c4-484c-a18d-40bb8ebc0f26
Location
Friendship Manor
917 NW Summit St, Blue Springs, MO
Phone: (816) 228-5400
917 NW Summit St, Blue Springs, MO
Phone: (816) 228-5400
Owner
Attn: Friendship Manor
Friendship Manor
917 NW Summit St, Blue Springs, MO 64015
Phone: (000) 000-0000
Email: 0622@nationalchurchresidences.org
Friendship Manor
917 NW Summit St, Blue Springs, MO 64015
Phone: (000) 000-0000
Email: 0622@nationalchurchresidences.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | packing gland is leaking excessively, pit bucket overflows between maintenance visits, packing gland needs replaced | 8/6/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the pit, hydraulic oil all over the pit floor from overflowing pit bucket | 8/6/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | monthly fire service test log is not posted in the machine room | 8/6/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | the crosshead data tag has the capacity as 2500, the car operating panel has the capacity as 2000, the tag on the pump unit in the machine room has the capacity as 2000. put the correct capacity of 2000 on the crosshead data tag | 8/18/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | display the current copy of the state operating certificate in the machine room when received from the state, the certificate in the machine room expired in 2015 | 8/18/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(c) On-Site Maintenance Records (Other Records) | No | No | A record of findings for firefighters’ service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be kept in the machine room. | 8/18/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | repair the access door latch for the fire service phase 2 door in the car operating panel, the latch is not working correctly and the door is being held closed with duct tape | 8/18/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | The Monthly fire service test log in the machine room is not being filled out does not have any entries for 2024 on the log | 10/10/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display the current copy of the state operating certificate in the machine room, the one in the certificate frame expired in 2015 | 10/10/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the pit | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | No | Battery lowering unit has been removed from the controller, repair battery lowering unit (3.26.10) |