Inspection
Inspection Details
Equipment ID
9898
9898
Inspection Date
7/29/2024
7/29/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Michael Beachner
Michael Beachner
Relief Valve Pressure
n/a
n/a
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
14
14
External ID
7b633bac-c057-4d28-bbb6-8c5551d5c754
7b633bac-c057-4d28-bbb6-8c5551d5c754
Location
IREC Bldg-
1509 W Truman Rd, Independence, MO
Phone: (816) 521-5320
1509 W Truman Rd, Independence, MO
Phone: (816) 521-5320
Owner
Attn: Sarah Barker
Independence School District
201 N Forest Ave, Independence, MO 64055
Phone: (816) 521-5330 Ext: 61007
Email: SARAH_BARKER@isdschools.org
Independence School District
201 N Forest Ave, Independence, MO 64055
Phone: (816) 521-5330 Ext: 61007
Email: SARAH_BARKER@isdschools.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Adjust relating on two speed hoistway doors to get a minimum of 1/2 inch overlap on the landing marked "1", currently there is less than that in overlap creating a pinch hazzard | 3/12/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Provide Maintenance Records Log | 3/12/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | The Maintenance Control Program (MCP) On-Site documents are not in the machine room. | 1/3/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | The firefighters service test log is not being filled out monthly. | 1/3/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | replace burnt out pit light bulbs | 1/3/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Could not find Maintenance Control Program (MCP) documents in the machine room | 10/27/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | the fire service test log in the machine room is not being filled out monthly | 10/27/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | 1st floor hoistway door closer needs to be adjusted, will not self close last two inches | 10/27/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | 3rd floor hoistway door closer needs to be adjusted, will not self close last two inches | 10/27/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Repair machine room lights that are not working, required to have all the light fixtures working above the running equipment | 10/27/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Replace missing pit light bulb | 10/27/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Yes | No | Repair machine room lights that are not working, required to have all the light fixtures working above the running equipment. repeat violation | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | Yes | the brake stopped the rotation of the drive sheave and the Ropes slid over the drive sheave during the 125% brake test. Elevator slid onto the final limit, elevator red tagged until passes 125% test. Counterweight balance is around 35% Item 2.27.2.1(1) |