Inspection
Inspection Details
Equipment ID
15022
15022
Inspection Date
11/6/2017
11/6/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Unknown Conversion
Unknown Conversion
Mechanic Name
Relief Valve Pressure
360
360
Slide
Governor Rope Pull
Door Closing Force
19
19
External ID
Location
Centenary United Methodist
55 Plaza Square, St. Louis, MO
Phone: (314) 421-3136
55 Plaza Square, St. Louis, MO
Phone: (314) 421-3136
Owner
Centenary United Methodist
55 Plaza Square, St. Louis, MO 63103
55 Plaza Square, St. Louis, MO 63103
Billing
Attn: Centenary United Methodist
55 Plaza Square, , MO 63103
55 Plaza Square, , MO 63103
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Fire extinguisher is out of date. | 12/6/2018 |
| conversion | conversion | n/a | No | No | Machine room door shall be self-locking and self-closing. | 12/6/2018 |
| conversion | conversion | n/a | No | No | All pipes above or in close proximity of the elevator equipment shall be guarded or guttered. | 12/6/2018 |
| conversion | conversion | n/a | No | No | Lighting in the machine room shall be 10 foot candles at the floor. | 12/6/2018 |
| conversion | conversion | n/a | No | No | Machine room shall be cleaned of all materials and equipment not necessary for the maintenance and operation of the elevator. | 12/6/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | No | No | Machine room lighting shall be 10 ftc at the floor. | 12/6/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 8.11.2.1.2(h) | No | No | Gutter and/or guard overhead pipes. | 12/6/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher is out of date. A current tested, ABC type fire extinguisher shall be provided in the machine room. | 10/28/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 12/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | Machine room door shall be self-closing and self-locking. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.2 - Stop switches | 2.26.2.5 | Yes | No | Stop switch shall be wired to alarm for audible notification. |