Inspection
Inspection Details
Equipment ID
23444
23444
Inspection Date
10/8/2024
10/8/2024
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
James VanZant
James VanZant
Mechanic Name
Paul Bartlett
Paul Bartlett
Relief Valve Pressure
Slide
1 in
1 in
Governor Rope Pull
30/120
30/120
Door Closing Force
21
21
External ID
75b8ea10-0d4e-4b9a-840c-f6bf0c410d0a
75b8ea10-0d4e-4b9a-840c-f6bf0c410d0a
Location
Bear Village Phase 5
943 S Kimbrough Ave, Springfield, MO
Phone: (417) 864-6303
943 S Kimbrough Ave, Springfield, MO
Phone: (417) 864-6303
Owner
Attn: Bryan Properties
Bryan Properties
519 E Walnut St, Springfield, MO 65806
Phone: (417) 864-6303
Email: travis@bryan-properties.net
Bryan Properties
519 E Walnut St, Springfield, MO 65806
Phone: (417) 864-6303
Email: travis@bryan-properties.net
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate | 12/7/2020 |
| A17.1-2016 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Room and Machinery Space | No | No | Unauthorized Material in machine room | 12/7/2020 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | Maintenance records required | 12/7/2020 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post certificate | 2/1/2022 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Required to be checked monthly | 2/1/2022 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone Failed | 12/7/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | No | No | No records | 2/1/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No Records | 9/18/2024 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone Failed | 9/13/2023 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Fireman's Recall system is to be checked monthly | 9/18/2024 |
| A17.1-2016 : Elevators | 2.4 - Machine space | 8.6.4.8 Machine Room and Machinery Space | No | No | Unauthorize material | 9/18/2024 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated one | 9/18/2024 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Fireman's recall is to be checked monthly. | 9/18/2024 |