Inspection
Inspection Details
Equipment ID
6419
6419
Inspection Date
10/11/2024
10/11/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Vernon Livergood
Vernon Livergood
Mechanic Name
Paul Jaremko
Paul Jaremko
Relief Valve Pressure
420
420
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
8551b4fd-cb7a-484e-b83a-80c5ac5f331c
8551b4fd-cb7a-484e-b83a-80c5ac5f331c
Location
Farmers Bank
123 E 3rd St, Cameron, MO
Phone: (000) 000-0000
123 E 3rd St, Cameron, MO
Phone: (000) 000-0000
Owner
Attn: Darrel Howell
Farmers State Bank
124 E 3RD ST, CAMERON, MO 64429
Phone: (816) 632-6641
Email: dhowell@fscbank.com
Farmers State Bank
124 E 3RD ST, CAMERON, MO 64429
Phone: (816) 632-6641
Email: dhowell@fscbank.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide type ABC fire extinguisher inside machine room next to access door. | 11/3/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room access door needs to be self-closing. | 11/3/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove non-elevator related material from machine room. | 11/3/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor | 11/3/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light does not illuminate | 10/17/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room access door shall be self-locking | 12/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Post In Case of Fire signage next to hall button fixture at each landing | 12/9/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Seal hole that penetrates hoistway wall at lobby landing. | 12/9/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Remove exposed non-elevator related wiring from the hoistway enclosure. | 12/9/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | State operating certificate not displayed | 12/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light does not operate | 10/11/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Remove non-elevator related wiring from the hoistway | 12/9/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | State operating certificate not displayed | 12/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Post In Case of Fire signage next to hall button fixture at each landing | 12/9/2025 |