Inspection
Inspection Details
Equipment ID
21270
21270
Inspection Date
10/10/2024
10/10/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Christian Schickedanz
Christian Schickedanz
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
d67fed6f-b2ce-4a7f-ad1d-7a54b8a24919
d67fed6f-b2ce-4a7f-ad1d-7a54b8a24919
Location
Michaels
1516 S Brentwood Blvd, Brentwood, MO
Phone: (314) 918-8189
1516 S Brentwood Blvd, Brentwood, MO
Phone: (314) 918-8189
Owner
Attn: MICHAEL'S c/o Pace Properties
Pace Properties- Brentwood
1401 S Brentwood Blvd, Brentwood, MO 63144
Phone: (469) 759-5366
Alt Phone: (469) 621-0908
Email: DMF.Escalation@michaels.com
Pace Properties- Brentwood
1401 S Brentwood Blvd, Brentwood, MO 63144
Phone: (469) 759-5366
Alt Phone: (469) 621-0908
Email: DMF.Escalation@michaels.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Demarcation lights shall work | 2/9/2022 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current certificate. | 1/10/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.11.4.2.13 Escalator Handrail Safety Systems | Yes | No | Replace both handrails (cracking) | 10/10/2024 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 1/10/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.4 Escalator Combplates | No | No | Replace sections of comb plates top and bottom entrances, missing teeth | 10/16/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.4 Escalator Combplates | Yes | No | Adjust upper comb plate upthrust switch | 10/10/2024 |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Complete annual test within 30 days, test brake torque | 10/10/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.6.8.1 | Yes | No | Replace cracked left handrail and right handrail | 11/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.7 - Combplate and comb step impact device | 6.1.8.3 | Yes | No | Replace broken comb plates one at top one at bottom | 11/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.7 - Reversal stop switch | 6.1.6.3.8 | Yes | Yes | Replace inoperative anti reversal switch | 11/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 6.1.7.2 | Yes | No | Provide NFPA 70 compliant wiring to demarcation lights | 11/22/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 10/16/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.4 Escalator Combplates | No | No | Replace damaged comb plates (one at each end), or as needed. | 10/16/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.6.8.1 | No | No | Both handrails are cracked, have pinch points. Replace same | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3 Step/Skirt Performance Index | Yes | No | Step indexing measurements are above allowable tolerances, need repaired. Re-inspection required |