Inspection
Inspection Details
Equipment ID
15556
15556
Inspection Date
10/15/2024
10/15/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Timothy Trout
Timothy Trout
Mechanic Name
Benjamin Kurzava
Benjamin Kurzava
Relief Valve Pressure
420
420
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
26
26
External ID
c94e8f17-eef5-4bdd-99ab-8942eef58f61
c94e8f17-eef5-4bdd-99ab-8942eef58f61
Location
Tolbert, Beadle
3010 E BATTLEFIELD ST, SPRINGFIELD, MO
Phone: (417) 839-2040
3010 E BATTLEFIELD ST, SPRINGFIELD, MO
Phone: (417) 839-2040
Owner
Attn: Terry Tolbert
Tolbert, Beadle LLC
3010 E Battlefield St, Springfield, MO 65804
Phone: (417) 887-3010
Email: terry@tolbertbeadle.com
Tolbert, Beadle LLC
3010 E Battlefield St, Springfield, MO 65804
Phone: (417) 887-3010
Email: terry@tolbertbeadle.com
Billing
Attn: William Beadle
Tolbert, Beadle LLC
3010 E Battlefield St, Springfield, MO 65804
Phone: (417) 887-3010
Email: wbeadle@tolbertbeadle.com
Tolbert, Beadle LLC
3010 E Battlefield St, Springfield, MO 65804
Phone: (417) 887-3010
Email: wbeadle@tolbertbeadle.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | repair or replace the emergency phone as the incoming line is dead | 11/10/2020 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(d) | No | No | provide a maintenance control program in the machine room | 11/20/2020 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | obtain and display a current state operating certificate in the machine room | 11/20/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Replace the rusted-out sump pit cover. | 8/22/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room | 8/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Have the fire extinguisher re-certified! | 8/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Obtain an MCP document from Otis to leave in the machine room | 8/22/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room | 8/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair the emergency phone as there is no dial tone. Call for re-inspection within 14 days. | 1/17/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.6 Sump Pump Covers | No | No | Replace the rusted out sump pit cover. | 8/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | clean up the oil and water from the pit. You must mmaintain a dry pit. | 8/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.8 | No | No | Replace all the electrical conduit and wiring and fixtures in the pit with NEMA 4 rated equipment per NFPA 70. AS they have been submerged under water for a long period of time and are corroded badly . | 8/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Have the fire extinguisher re-certified. | 10/27/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room | 10/27/2024 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | Provide an MCP document in the machine room. | 10/27/2024 |