Inspection
Inspection Details
Equipment ID
3475
3475
Inspection Date
10/16/2024
10/16/2024
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Ronald Edwards
Ronald Edwards
Mechanic Name
Kyle Ritchhart
Kyle Ritchhart
Relief Valve Pressure
450
450
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
22
22
External ID
da714073-3078-46fc-9b39-39fbc9330555
da714073-3078-46fc-9b39-39fbc9330555
Location
Belleview Office Bldg
4770 N Belleview Ave, Kansas City, MO
Phone: (816) 474-9340
4770 N Belleview Ave, Kansas City, MO
Phone: (816) 474-9340
Owner
Attn: Belleview Properties LLC
Belleview Properties LLC
4770 N Belleview Ave, Kansas City, MO 64116
Phone: (000) 000-0000
Belleview Properties LLC
4770 N Belleview Ave, Kansas City, MO 64116
Phone: (000) 000-0000
Billing
Attn: McKee Commercial
McKee Commercial
PO Box 180980, Coronado, CA 92178
Phone: (619) 642-2711
Email: lgrum@mckeecompany.com
McKee Commercial
PO Box 180980, Coronado, CA 92178
Phone: (619) 642-2711
Email: lgrum@mckeecompany.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | Yes | No | phone not working | 9/2/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No current operating cirt. displayed | 2/26/2026 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | Need proper MCP on site | 2/26/2026 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emg. phone not working. | 9/9/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | self closer not working on mach. room door | 2/26/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | car door restrictor not working | 9/9/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | no current cirt. of operation displayed | 2/26/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | no current cirt displayed | 2/26/2026 |
| A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | Yes | No | door restrictor not working | 9/5/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone not working. Bldg line? | 2/26/2026 |
| A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | Yes | No | Car door restrictor broken | 2/26/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Control valve check valve bleeding back excessively. Repair | 2/26/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Update the machine room fire extingusher. |